Rescinding Spent Fuel Pool Exclusion Regulations

Federal Register, Volume 80 Issue 171 (Thursday, September 3, 2015)

Federal Register Volume 80, Number 171 (Thursday, September 3, 2015)

Proposed Rules

Pages 53266-53272

From the Federal Register Online via the Government Publishing Office www.gpo.gov

FR Doc No: 2015-21834

=======================================================================

-----------------------------------------------------------------------

NUCLEAR REGULATORY COMMISSION

10 CFR Part 51

Docket Nos. PRM-51-29; NRC-2012-0215

Rescinding Spent Fuel Pool Exclusion Regulations

AGENCY: Nuclear Regulatory Commission.

ACTION: Petition for rulemaking; denial.

-----------------------------------------------------------------------

SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is denying a petition for rulemaking (PRM), PRM-51-29, submitted by the Commonwealth of Massachusetts (the Commonwealth or the petitioner). The petitioner requested that, in light of information gained from the Fukushima Dai-

ichi accident, the NRC rescind its regulations that make a generic determination that spent fuel pool storage does not have a significant environmental impact for nuclear power plant license renewal actions. The NRC is denying the petition because the NRC finds no basis to consider a rulemaking to revise such regulations.

DATES: The docket for the petition for rulemaking, PRM-51-29, is closed on September 3, 2015.

ADDRESSES: Please refer to Docket ID NRC-2012-0215 when contacting the NRC about the availability of information for this action. You may obtain publicly-available information related to this action by any of the following methods:

Federal Rulemaking Web site: Go to http://www.regulations.gov and search for Docket ID NRC-2012-0215. Address questions about NRC dockets to Carol Gallagher; telephone: 301-415-

3463; email: Carol.Gallagher@nrc.gov. For technical questions, contact the individual listed in the FOR FURTHER INFORMATION CONTACT section of this document.

NRC's Agencywide Documents Access and Management System (ADAMS): You may obtain publicly-available documents online in the ADAMS Public Documents collection at http://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``ADAMS Public Documents'' and then select ``Begin Web-based ADAMS Search.'' For problems with ADAMS, please contact the NRC's Public Document Room (PDR) reference staff at 1-800-397-4209, 301-415-4737, or by email to pdr.resource@nrc.gov. The ADAMS accession number for each document referenced (if it is available in ADAMS) is provided the first time that it is mentioned in the SUPPLEMENTARY INFORMATION section. For the convenience of the reader, instructions about obtaining materials referenced in this document are provided in Section IV, Availability of Documents.

NRC's PDR: You may examine and purchase copies of public documents at the NRC's PDR, Room O1-F21, One White Flint North, 11555 Rockville Pike, Rockville, Maryland 20852.

FOR FURTHER INFORMATION CONTACT: Jenny Tobin, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington, DC 20555-

0001; telephone: 301-415-2328; email: Jennifer.Tobin@nrc.gov.

SUPPLEMENTARY INFORMATION:

Table of Contents

  1. The Petition

  2. Reasons for Denial

  3. Conclusion

  4. Availability of Documents

  5. The Petition

    On June 2, 2011, before the NRC's Atomic Safety and Licensing Board (ASLB), the Commonwealth of Massachusetts, Office of the Attorney General, Environmental Protection Division, requested a waiver of the NRC's generic determination regarding spent fuel pool (SFP) storage impacts in the Pilgrim nuclear power plant (NPP) license renewal proceeding. The petitioner also requested that, if the ASLB rejected the Commonwealth's waiver, then the NRC should consider the waiver request to be a PRM. Specifically, the petitioner requested that the NRC's regulations in Sec. 51.71(d) \1\ of Title 10 of the Code of Federal Regulations (10 CFR) and table B-1 \2\ in appendix B to subpart A of 10 CFR part 51 be revised because these regulations, according to the petitioner, incorrectly

    Page 53267

    ``generically classify the environmental impacts of high-density pool storage of spent fuel as insignificant and thereby permit their exclusion from consideration in environmental impact statements (EISs) for renewal of nuclear power plant operating licenses.''

    ---------------------------------------------------------------------------

    \1\ 10 CFR 51.71 is entitled, ``Draft environmental impact statement- contents''; Sec. 51.71(d) describes the analysis required to be included in the draft EIS. For license renewal, the draft supplemental EIS (1) relies on supporting information in NUREG-1437, ``Generic Environmental Impact Statement GEIS for License Renewal of Nuclear Plants,'' for generic issues and (2) provides an analysis for the site-specific issues.

    \2\ Table B-1 is entitled, ``Summary of Findings on NEPA Issues for License Renewal of Nuclear Power Plants,'' and is the codification of the GEIS. In table B-1, generic issues are designated as ``Category 1'' issues and site-specific issues are designated as ``Category 2'' issues.

    ---------------------------------------------------------------------------

    The petitioner asserted that the Fukushima Dai-ichi accident provides ``new and significant'' information that would affect the NRC's impact analysis for SFPs in license renewal. The petitioner contends that this event provides the justification for its request that the NRC revise 10 CFR 51.71(d) and table B-1 in appendix B to subpart A of 10 CFR part 51. The petitioner made the following three claims:

    1. The impacts from the onsite storage of spent fuel are understated in NUREG-1437, ``Generic Environmental Impact Statement GEIS for License Renewal of Nuclear Plants,'' because the Fukushima Dai-ichi event indicates that the probability-weighted consequences of a spent fuel pool accident are greater than what was considered in the GEIS.

    2. The impacts from the onsite storage of spent fuel are understated in the license renewal GEIS analysis because the mitigation measures implemented at NPPs after the September 11, 2001 (9/11), terrorist attacks will not effectively mitigate the impacts of SFP accidents, given the new information gained from the Fukushima accident along with the NRC's policy of imposing secrecy on the mitigation measures, and the mitigation measures were improperly relied upon in the denial of PRM-51-10.\3\

    ---------------------------------------------------------------------------

    \3\ The request presented in the petition is essentially identical to the request presented in another PRM submitted by the Commonwealth on August 25, 2006, PRM-51-10 (ADAMS Accession No. ML081890124) (although the basis for the request in each case is unique). The State of California also submitted a petition, PRM-51-

    12, in 2007 that was nearly identical to PRM-51-10. The NRC denied PRM-51-10 and PRM-51-12 on August 8, 2008 (73 FR 46204). The NRC's denials of these two petitions were upheld. New York v. U.S. Nuclear Regulatory Commission, 589 F.3d 551 (2nd Cir. 2009). The arguments presented in support of PRM-51-10 are similar to those presented in support of this petition.

    ---------------------------------------------------------------------------

    3. The license renewal GEIS impact analysis must address spent fuel storage impacts on a site-specific, rather than generic basis.

    On December 13, 2011, the ASLB denied the Commonwealth's waiver petition (LBP-11-35). On March 8, 2012, in Memorandum and Order CLI-12-

    06, the Commission affirmed the ASLB's denial of the waiver request and granted the Commonwealth's alternative request that its waiver request be treated as a PRM; the petition was referred to the NRC staff. The NRC assigned the petition Docket No. PRM-51-29. The NRC published a notice of receipt of the petition in the Federal Register (FR) on December 19, 2012 (77 FR 75065), and supplemented the notice on December 31, 2012 (77 FR 76952). The NRC did not request public comment on the petition because sufficient information was available for the NRC staff to form a technical opinion regarding the merits of the petition, which is similar to the Commonwealth's previous petition (PRM-51-10).

    For the purposes of this review, the issues that the petitioner raised about the Pilgrim NPP licensing proceeding were considered generically, to the extent practicable. Other statements concerning the Pilgrim NPP license renewal proceeding, including those concerns related to the risk of severe reactor accidents, are beyond the scope of this PRM.

  6. Reasons for Denial

    The NRC complies with Section 102(2) of the National Environmental Policy Act of 1969 (NEPA) in its consideration of NPP license renewal applications through the implementation of its environmental protection regulations in 10 CFR part 51. In accordance with 10 CFR 51.95(c), the NRC relies upon its environmental impact statement, NUREG-1437, ``Generic Environmental Impact Statement GEIS for License Renewal of Nuclear Plants,'' as the basis for environmental reviews of NPP license renewal actions. The NRC published the GEIS in May 1996 (1996 GEIS) and then revised and updated it in June 2013 (2013 GEIS).\4\ The GEIS reflects lessons learned and knowledge gained during previous license renewal environmental reviews and describes the potential environmental impacts of renewing the operating license of a NPP for up to an additional 20 years. The findings of the GEIS have been codified into table B-1, ``Summary of Findings on NEPA Issues for License Renewal of Nuclear Power Plants,'' in appendix B to subpart A of 10 CFR part 51.\5\

    ---------------------------------------------------------------------------

    \4\ The NRC's regulations in 10 CFR 51.95(c) require, for the consideration of potential environmental impacts of renewing a NPP's operating license under 10 CFR part 54, that the NRC prepare an environmental impact statement, which is a supplement to the 2013 GEIS. At the time the petition was filed in 2011, 10 CFR 51.95(c) referred to the initial 1996 GEIS. The NRC published a notice of issuance for the updated 2013 GEIS on June 20, 2013 (78 FR 37325).

    \5\ See Baltimore Gas and Elec. Co. v. NRDC, 462 U.S. 87, 100-

    01, 103 S. Ct. 2246 (1983) (upholds use of generic environmental analyses) and Massachusetts v. NRC, 708 F.3d 63, 68 (1st Cir. 2013) (``the Supreme Court has held that the NRC is permitted to make generic determinations to meet its NEPA obligations'').

    ---------------------------------------------------------------------------

    The NRC classifies the license renewal issues described in the GEIS as either generic or site-specific. Generic issues (i.e., environmental impacts common to all nuclear power plants) are addressed in the GEIS. Site-specific issues are addressed initially by the license renewal applicant (i.e., a nuclear power plant licensee seeking a renewal of its operating license under the NRC's license renewal regulations in 10 CFR part 54) in its environmental report, which is required by 10 CFR 51.45, and then by the NRC in a supplemental environmental impact statement (SEIS) prepared for each license renewal application. The plant-specific SEIS and the GEIS, together, constitute the NRC's NEPA analysis for any given NPP license renewal action. In table B-1, the ``Onsite storage of spent nuclear fuel'' issue has been classified as a Category 1, or generic, issue with an impact level finding of ``small.'' The ``Onsite storage of spent nuclear fuel'' finding states ``the expected increase in the volume of spent fuel from an additional 20 years of operation can be safely accommodated onsite during the license renewal term with small environmental effects through dry or pool storage at all plants.'' The designation of an issue as a Category 1 (generic resolution) issue in the GEIS does not mean that potential impacts cannot be considered in a license renewal SEIS. If there are changes in plant operating parameters or new and significant information pertinent to an evaluation of impacts, these are considered during preparation of plant-specific supplements to the NRC's license renewal GEIS.

    Under 10 CFR part 51, neither the applicant's environmental report nor the NRC's SEIS is required to address issues previously resolved generically, as set forth in the GEIS and table B-1, absent new and significant information. Section 51.92(a)(2) requires a supplement to an EIS if there is new and significant information relevant to environmental concerns and bearing on the license renewal or its impacts. The NRC standard for the evaluation of ``new and significant'' information is that the information must present ``a seriously different picture of the environmental impact of the proposed project from what was previously envisioned.'' \6\ Therefore, to be

    Page 53268

    ``significant,'' any information must lead to a conclusion seriously different than that currently set forth in the GEIS.\7\

    ---------------------------------------------------------------------------

    \6\ Union Electric Company d/b/a Ameren Missouri (Callaway Plant, Unit 2), et al, CLI-11-05, 74 NRC 141, 167-68 (2011) quoting Hydro Resources, Inc., CLI-99-22, 50 NRC 3, 14 (1999) (alteration in the original) (supporting citations omitted) (``To merit this additional review, information must be both `new' and `significant,' and it must bear on the proposed action or its impacts. As we have explained, `the new information must present a seriously different picture of the environmental impact of the proposed project from what was previously envisioned'.''); see also Sierra Club v. Froehlke, 816 F.2d 205, 210 (5th Cir. 1987) (alteration added) (supporting citations omitted) (``In making its determination whether to supplement an existing EIS because of new information, the United States Army, Corps of Engineers should consider `the extent to which the new information presents a picture of the likely environmental consequences associated with the proposed action not envisioned by the original EIS'.''); Wisconsin v. Weinberger, 745 F.2d 412, 418 (7th Cir.1984) (supplementation required where new information ``provides a seriously different picture of the environmental landscape.'').

    \7\ See Regulatory Guide 4.2, Supplement 1, Preparation of Supplemental Environmental Reports for Applications to Renew Nuclear Power Plant Operating Licenses, Chapter 5 (September 2000), and Revision 1 published June 20, 2013 (78 FR 37324).

    ---------------------------------------------------------------------------

    The petitioner claimed that the Fukushima nuclear accident, including possible damage to the SFP, provides new and significant information that requires the NRC to reconsider its impact findings in the license renewal GEIS. With respect to the March 2011 Fukushima accident, a Japanese government report, issued in June 2011, found that the Fukushima Dai-ichi, Unit 4 spent fuel pool, the one believed to have sustained the most serious damage, actually remained ``nearly undamaged.'' \8\ The report noted that visual inspections found no water leaks or serious damage to the Unit 4 spent fuel pool. Additionally, on April 25, 2014, the NRC issued a report entitled, ``NRC Overview of the Structural Integrity of the Spent Fuel Pool at Fukushima Dai-ichi, Unit 4.'' The results indicated that the structural integrity of the Unit 4 spent fuel pool was sound.

    ---------------------------------------------------------------------------

    \8\ See ``Report of Japanese Government to the IAEA Ministerial Conference on Nuclear Safety-The Accident at TEPCO's Fukushima Nuclear Power Stations,'' IV-91. English version available at http://www.kantei.go.jp/foreign/kan/topics/201106/iaea_houkokusho_e.html, last visited on July 15, 2015.

    ---------------------------------------------------------------------------

    With respect to the Fukushima event, the Commission has taken action to mitigate beyond design basis external events, including imposing new requirements to develop mitigating strategies for beyond design basis external events, to install hardened severe accident capable vents for boiling water reactors with Mark I and II containments, to install reliable SFP water level instrumentation, to re-evaluate seismic and flooding hazards, and to enhance emergency preparedness capabilities.\9\

    ---------------------------------------------------------------------------

    \9\ Order EA-12-051, ``NRC Order on Spent Fuel Pool Instrumentation,'' dated March 12, 2012; Order EA-12-049, ``NRC Order on Mitigating Strategies,'' dated March 12, 2012; Order EA-13-

    109, ``NRC Order on Severe Accident Capable Hardened Vents,'' dated June 6, 2013; 10 CFR 50.54(f) letters were issued on March 12, 2012, to NPP licensees for seismic/flooding re-evaluations and assessing emergency response capabilities.

    ---------------------------------------------------------------------------

    The accident at the Fukushima Dai-ichi NPP in Japan led to additional questions about the safe storage of spent fuel and whether the NRC should require the expedited transfer of spent fuel from spent fuel pools to dry cask storage at nuclear power plants in the United States. This issue was identified by the NRC staff subsequent to the ``Near-Term Task Force NTTF Review of Insights from the Fukushima Dai-ichi Accident'' report. At the time this issue was identified, the NRC staff recognized that further study was needed to determine if regulatory action was warranted. On October 9, 2013, the NRC released a report, NUREG-2161, ``Consequence Study of a Beyond-Design-Basis Earthquake Affecting the Spent Fuel Pool for a U.S. Mark I Boiling Water Reactor'' (the ``Spent Fuel Pool Study''). Additionally, the NRC conducted a regulatory analysis in COMSECY-13-0030, ``Staff Evaluation and Recommendation for Japan Lessons Learned Tier 3 Issue on Expedited Transfer of Spent Fuel,'' dated November 12, 2013. This study and the regulatory analysis concluded that SFPs are very robust structures with large safety margins, and that regulatory actions to reduce the amount of fuel in the spent fuel pool were not warranted. The Commission subsequently concluded in SRM-COMSECY-13-0030, issued on May 23, 2014, that further regulatory action need not be pursued in light of the low risk of accident for SFP storage.

    As will be discussed in more detail in response to Issues 1 and 2, the event at Fukushima Dai-ichi does not provide any new and significant information that would have materially altered the conclusions in the GEIS, or in its underlying assumptions.\10\

    ---------------------------------------------------------------------------

    \10\ While the ASLB and Commission were principally concerned with the petitioner's claims regarding reactor accidents, not SFP accidents (both were held to be out of scope of the Pilgrim NPP license renewal process), the condition of the SFP at Fukushima Dai-

    ichi, Unit 4, did not support the petitioner's position that impacts from the earthquake constituted new and significant information. In LBP-11-35, the ASLB observed that the event at Fukushima did not demonstrate new and significant information in the Pilgrim NPP license renewal proceeding.

    ---------------------------------------------------------------------------

    In the petition, the Commonwealth raises three principal arguments; each is summarized and evaluated in the subsequent discussion.

    Issue 1: The Petitioner Asserts That the Impacts From the Onsite Storage of Spent Fuel Are Understated in the License Renewal GEIS Analysis Because the Fukushima Dai-Ichi Event Indicates That the Probability-Weighted Consequences of a Spent Fuel Pool Accident Are Greater Than What Was Considered in the GEIS

    The petitioner argued that the Fukushima event provided new and significant information challenging the generic conclusions in the license renewal GEIS. Specifically, the petitioner claimed that ``the Fukushima accident shows . . . there is a substantial conditional probability of a pool fire during or following a reactor accident'' and that ``this relationship between a pool fire and a core melt accident is not addressed in the License Renewal GEIS'' or the denial of PRM 51-

    10 (73 FR 46204; August 8, 2008).\11\ Further, the petitioner referenced a report by Dr. Gordon Thompson, ``New and Significant Information from the Fukushima Dai-ichi Accident in the Context of Future Operation of the Pilgrim Nuclear Power Plant'' (the ``Thompson Report''), to support its argument that the GEIS understates the probability and impacts of an SFP accident.

    ---------------------------------------------------------------------------

    \11\ PRM at 27.

    ---------------------------------------------------------------------------

    NRC Response to Issue 1

    The evaluation of the environmental impacts of the onsite storage of spent nuclear fuel during the license renewal term, including potential spent fuel pool accidents, was documented in the 1996 GEIS and reaffirmed in the 2013 GEIS. Based on this evaluation, the ``Onsite storage of spent nuclear fuel'' NEPA issue in table B-1 has been classified as a Category 1 issue, or as a generic issue, with a probability-weighted impact level finding of ``small.'' \12\

    ---------------------------------------------------------------------------

    \12\ For most table B-1 NEPA issues, the NRC determined whether the impacts of license renewal would have a small, moderate, or large environmental impact. The statements of consideration for the June 20, 2013, rulemaking note that ``a small impact means that the environmental effects are not detectable, or are so minor that they would neither destabilize nor noticeably alter any important attribute of the resource. A moderate impact means that the environmental effects are sufficient to alter noticeably, but not destabilize, important attributes of the resource. A large impact means that the environmental effects would be clearly noticeable and would be sufficient to destabilize important attributes of the resource'' (78 FR 37285).

    ---------------------------------------------------------------------------

    First, the petitioners' assertion that the Fukushima event revealed a previously unconsidered aspect of spent fuel storage is incorrect. In response to PRM-51-10, the Commission rejected a similar argument regarding the probability ``that a severe accident at the

    Page 53269

    adjacent reactor would result in a SFP zirconium fire.'' \13\ The Commission noted that a series of unlikely events must occur for a severe reactor accident to lead to a spent fuel pool fire, including the accident itself, ``containment failure or bypass,'' ``loss of SFP cooling,'' ``extreme radiation levels precluding personnel access,'' ``inability to restart cooling or makeup systems due to extreme radiation doses,'' ``loss of most or all pool water through evaporation,'' and ``initiation of a zirconium fire in the SFP.'' \14\ As a result, the Commission concluded that ``the probability of a SFP zirconium fire due to a severe reactor accident and subsequent containment failure would be well below the Petitioners' 2E-5 per year estimate.'' \15\ The agency cited the denial of the PRM in the 2013 update to the GEIS.\16\ Therefore, the Commission has previously considered the probability of a severe reactor accident causing a spent fuel pool fire and found it to be low. Petitioners have not demonstrated how information regarding the Fukushima accident provides a seriously different picture of this issue.

    ---------------------------------------------------------------------------

    \13\ 73 FR at 46210.

    \14\ Id.

    \15\ Id.

    \16\ 2013 GEIS at E-38.

    ---------------------------------------------------------------------------

    Moreover, the NRC has completed several studies of SFP safety, including NUREG-1353, ``Regulatory Analysis for the Resolution of Generic Issue 82, `Beyond Design Basis Accidents in Spent Fuel Pools';'' NUREG-1738, ``Technical Study of Spent Fuel Pool Accident Risk at Decommissioning Nuclear Power Plants;'' and NUREG-2161, ``Consequence Study of a Beyond-Design-Basis Earthquake Affecting the Spent Fuel Pool for a U.S. Mark I Boiling-Water Reactor.'' These studies have all concluded that SFPs continue to provide adequate protection of public health and safety and are consistent with the findings in the 2013 GEIS that onsite storage of spent fuel during the license renewal term would have a small impact on the environment.

    On September 19, 2014, the Commission published the ``continued storage'' final rule (formerly known as the ``waste confidence rule,'' 79 FR 56238) and its associated generic environmental impact statement (NUREG-2157, ``Generic Environmental Impact Statement for Continued Storage of Spent Nuclear Fuel''), amending 10 CFR 51.23 to revise the generic determination on the environmental impacts of continued storage of spent nuclear fuel beyond the licensed life for operation of a reactor. The final rule also makes conforming changes to the ``Onsite storage of spent nuclear fuel'' issue finding under the ``Waste Management'' section in table B-1 in appendix B to subpart A of 10 CFR part 51. The final rule revises the finding to address both the impacts of onsite storage during the license renewal term and adds generic determinations of the environmental impacts of continued storage of spent nuclear fuel beyond a reactor's licensed life (i.e., those impacts that could occur as a result of the storage of spent nuclear fuel at at-reactor or away-from-reactor sites after a reactor has permanently shut down and until a permanent repository becomes available). The continued storage final rule affirms that the environmental impacts from the onsite storage of spent nuclear fuel, including potential spent fuel pool accidents, are small during the short-term storage timeframe (i.e., 60 years of continued storage after permanent shut down, after which the continued storage rule assumes that spent fuel will be moved to dry storage). This finding is consistent with the finding of the license renewal GEIS. Further, the Commission stated in the final rule that the direct and indirect environmental impacts of continued storage can be analyzed generically and that the impact determinations are not expected to differ from those that would result from individual site-specific reviews for the continued storage period. In reaching this result, the agency responded to a comment that suggested that the underlying analyses did not appropriately account for the possibility of a severe reactor accident leading to a spent fuel pool accident.\17\ The NRC disagreed with this comment, in part, based on the conservative aspects of the agency's previous studies of SFP accidents.\18\

    ---------------------------------------------------------------------------

    \17\ NUREG-2161 at D-438 to D-440.

    \18\ Id.

    ---------------------------------------------------------------------------

    As previously discussed, a report issued by the Japanese government in June 2011 found that the SFP at Fukushima Dai-ichi, Unit 4, the SFP which presented the highest safety concern among the SFPs, remained nearly undamaged. This report notes that from the analysis of nuclides in the water extracted from the spent fuel pool, it appears that no extensive damage occurred to the fuel rods. No serious damage to the pool, including water leaks, was found from visual inspections of the pool's condition. Additionally, on April 25, 2014, the NRC issued a report entitled, ``NRC Overview of the Structural Integrity of the Spent Fuel Pool at Fukushima Dai-ichi, Unit 4.'' The results indicated that the structural integrity of the Unit 4 spent fuel pool was sound. Consequently, the petitioners have not shown that the Fukushima event constitutes new and significant information regarding the probability of a SFP fire. For the reasons discussed previously, the PRM does not provide a seriously different picture of the agency's previous analyses of a spent fuel pool accident, which have all concluded that despite the potential for large consequences of a severe spent fuel pool accident, the probability-weighted consequences are small due to the low probability of such an event.

    Issue 2: The Petitioner Asserts That the Impacts From the Onsite Storage of Spent Fuel Are Understated in the License Renewal GEIS Analysis Because the Mitigation Measures Implemented After the September 11, 2001 (9/11), Terrorist Attacks Will Not Effectively Mitigate the Impacts of SFP Accidents, Given the New Information Gained From the Fukushima Accident Along With the NRC's Policy of Imposing Secrecy on the Mitigation Measures, and the Mitigation Measures Were Improperly Relied Upon in the Denial of PRM-51-10 (73 FR 46204)

    The petitioner claimed that information about the Fukushima accident undermines the following two conclusions from the Commission's denial of PRM-51-10 (73 FR 46204; August 8, 2008): (1) Post-9/11 mitigation measures relied upon by the NRC would permit recovery of lost water from spent fuel pools, and (2) the NRC's policy of imposing secrecy on these mitigation measures would not impair their effectiveness. With regard to the first claim, the petitioner argued that lessons learned from the Fukushima Dai-ichi event undermine the Commission's reliance on post-9/11 mitigation measures that enable recovery of lost water from SFPs to prevent the onset of fire or other accidents, and that therefore, the Commission's denial of PRM-51-10 must be reconsidered. With regard to the second claim, the petitioner referenced statements in a declaration provided by Dr. Gordon Thompson that the ``NRC's excessive secrecy degrades the licensee's capability to mitigate an accident.'' The petitioner asserted that by keeping the post-9/11 mitigation measures secret, ``the NRC also raises the risk that first-responders from the surrounding community, who may be called upon to assist in the implementation of the mitigation measures, will not have sufficient understanding of them to implement them effectively.''

    Page 53270

    The petitioner's 2006 petition (PRM-51-10) requested changes to the Commission's generic findings regarding the environmental impacts from onsite spent fuel pool storage during the license renewal period of an operating NPP. In its denial (73 FR 46204; August 8, 2008), the NRC noted that spent fuel pools are ``massive, extremely-robust structures designed to safely contain the spent fuel discharged from a nuclear reactor under a variety of normal, off-normal, and hypothetical accident conditions (e.g., loss of electrical power, floods, earthquakes, or tornadoes).''

    The petitioner asserted that the Fukushima accident demonstrates that the conclusions in the denial of PRM-51-10 were incorrect, and that in light of the new information about the Fukushima event, the NRC should reevaluate its impact analysis in the license renewal GEIS because the new information undermines the staff's position that the post-9/11 mitigation measures would prevent the onset of a spent fuel pool fire following an attack or other severe accident by permitting recovery of lost water.

    NRC Response to Issue 2

    The petitioner's fundamental claim is that new and significant information from the Fukushima accident undermines the conclusions the Commission reached in denying PRM-51-10. As previously discussed, a report issued by the Japanese government in June 2011 found that the SFP at Fukushima Dai-ichi, Unit 4, which presented the most safety concern, remained nearly undamaged. This report notes that no extensive damage in the fuel rods appears to have occurred, based on an analysis of SFP water. No serious damage to the pool, including water leaks, was found from visual inspections of the pool's condition. Additionally, on April 25, 2014, the NRC issued a report entitled, ``NRC Overview of the Structural Integrity of the Spent Fuel Pool at Fukushima Dai-ichi, Unit 4.'' The results indicated that the structural integrity of the Unit 4 spent fuel pool was sound.

    As the Commission noted in its 2008 denial of PRM-51-10, and as demonstrated by NUREG-1738 and subsequent SFP studies: (1) Spent fuel pools are robust structures capable of withstanding numerous hazards, (2) additional mitigation strategies are available to maintain cooling in the event of an incident that results in a loss of cooling water, and (3) the risk of SFP accidents is very low. Indeed, subsequent studies, such as NUREG-2161, conclude that spent fuel risks at the reference plant are very low. The Spent Fuel Pool Study also found that for the specific reference plant and earthquake analyzed, SFPs are likely to withstand severe earthquakes without leaking.

    The NRC's regulatory approach for maintaining the safety and security of power reactors, and therefore SFPs, is based upon robust designs that are coupled with a strategic triad of preventive/

    protective systems, mitigative systems, and emergency-preparedness and response. Licensees develop protective strategies in order to meet the NRC design-basis threat. As noted in the Commission's denial of PRM-51-

    10 and PRM-51-12 (73 FR 46204), studies conducted by Sandia National Laboratories also confirmed the effectiveness of additional mitigation strategies to maintain spent fuel cooling in the event the pool is drained and its initial water inventory is reduced or lost entirely. Based on this more recent information, and the implementation of additional strategies following September 11, 2001, the probability, and accordingly, the risk, of a SFP zirconium fire initiation is expected to be less than reported in NUREG-1738 and previous studies. Taken as a whole, these systems, personnel, and procedures provide reasonable assurance that public health and safety, the environment, and the common defense and security will be adequately protected.

    In addition, following the Fukushima Dai-ichi event, the NRC issued Order EA-12-049, which requires, in part, that licensees establish plans and procedures associated with restoring and maintaining SFP cooling capability following a beyond-design-basis external event. These enhancements will provide additional capability for mitigating events that result in SFP draining, beyond those already required. Therefore, as discussed previously, the NRC does not simply rely on the post September 11, 2001, mitigating strategies to conclude the probability of an SFP accident is small. Rather, the NRC relies on the robust nature of the SFPs, the low probability of a SFP fire, and other mitigating measures, as well. Moreover, petitioners concede that measures to add water were ultimately successful at Fukushima, and observations to date have not revealed any cladding damage.\19\ Consequently, the petitioner's information in PRM-51-29 regarding the effectiveness of measures does not present a seriously different picture of this issue.

    ---------------------------------------------------------------------------

    \19\ COMSECY-13-0030 at 2.

    ---------------------------------------------------------------------------

    The petitioner also asserted that treating the mitigation measures as sensitive information impacts their effectiveness. Certain aspects of the enhancements are security-related and not publicly available, but in general include the following: (1) Significant reinforcement of the defense capabilities for nuclear facilities; (2) better control of sensitive information; (3) enhancements in emergency preparedness to further strengthen the NRC's nuclear facility security program; and (4) implementation of mitigating strategies to deal with postulated events potentially causing loss of large areas of the plant due to explosions or fires, including those that an aircraft impact might create. These measures are outlined in greater detail in a memorandum to the Commission entitled, ``Documentation of Evolution of Security Requirements at Commercial Nuclear Power Plants with Respect to Mitigation Measures for Large Fires and Explosions,'' dated February 4, 2010.

    Plant-specific mitigation strategies are designated as security related information in accordance with the Commission's guidance in SECY-04-0191, ``Withholding Sensitive Unclassified Information Concerning Nuclear Power Reactors from Public Disclosure.'' However, there is publicly-available, industry-developed guidance on implementing these requirements. Specifically, the NRC endorsed NEI 06-

    12, ``B.5.b Phase 2 & 3 Submittal Guideline,'' in a letter from the NRC to NEI dated December 22, 2006. The NRC found NEI-06-12 is a generally acceptable means for licensees to meet the NRC's requirements associated with mitigating potential loss of large areas due to fires or explosions, as explained in SECY-11-0125, ``Issuance of Bulletin 2011-01, `Mitigating Strategies'.'' Therefore, the agency has made sufficient information available to the public regarding mitigation strategies. Moreover, petitioners have not alleged that the measures used to restore cooling to the SFPs during the Fukushima accident were developed under similar secret conditions or indicated how any such secrecy hindered the effectiveness of those measures.\20\

    ---------------------------------------------------------------------------

    \20\ E.g., Thompson Report at 21-23.

    ---------------------------------------------------------------------------

    Because the petitioner has not provided new and significant information about the 9/11 mitigation measures with respect to the effectiveness of the measures to provide water to the SFPs, there is no need to supplement the GEIS.

    Page 53271

    Issue 3: The License Renewal GEIS Impact Analysis Must Address Spent Fuel Storage Impacts on a Site-Specific, Rather Than Generic Basis

    The petitioner asserted that the NRC's generic findings in table B-

    1 in appendix B to subpart A of 10 CFR part 51 with respect to the Category 1 onsite storage of spent nuclear fuel issue would not be supportable where the Fukushima accident otherwise demonstrates that the environmental impacts could be significant and argued that these impacts must be evaluated on a plant-specific Category 2 basis. The petitioner specifically argued that the NRC has not considered the new information previously presented by the petitioner in PRM-51-10 that contradicts the NRC's conclusions regarding the environmental impacts of the onsite storage of spent nuclear fuel.

    NRC Response to Issue 3

    Spent fuel storage impacts during the license renewal term were evaluated in the 1996 GEIS. The NRC staff concluded that the impacts would be small for all plants and, therefore, the onsite storage of spent fuel during the license renewal term was designated a Category 1 issue. Specifically, the Commission concluded in the 1996 GEIS that continued storage of existing spent fuel and storage of spent fuel generated during the license renewal term can be accomplished safely and without significant environmental impacts, and that radiation doses will be well within regulatory limits. The 2013 update to the GEIS confirmed the 1996 evaluation.

    Further, the Commission affirmed the treatment of SFP storage impacts as Category 1 in 2008 upon denying the two petitions for rulemaking (PRM-51-10 and PRM-51-12). The two petitions requested that the NRC initiate a rulemaking concerning the environmental impacts of the high-density storage of spent nuclear fuel in SFPs. The two petitions asserted that ``new and significant information'' shows that the NRC incorrectly characterized the environmental impacts of high-

    density spent fuel storage as ``insignificant'' in the 1996 GEIS for the renewal of nuclear power plant licenses. Specifically, the petitioner at that time asserted that spent fuel stored in high-density SFPs is more vulnerable to a zirconium fire than the NRC concluded in its analysis in the 1996 GEIS. On August 8, 2008, the Commission denied the petitions, stating:

    Based upon its review of the petitions, the NRC has determined that the studies upon which the Petitioners rely do not constitute new and significant information. The NRC has further determined that its findings related to the storage of spent nuclear fuel in pools, as set forth in NUREG-1437 and in Table B-1, of Appendix B to Subpart A of 10 CFR part 51, remain valid. Thus, the NRC has met and continues to meet its obligations under NEPA. For the reasons discussed previously, the Commission denies PRM-51-10 and PRM-51-12.

    Likewise here, because the impacts from SFP storage have been consistently demonstrated to be small and because the events in Japan do not challenge the NRC's assumptions or conclusions as to the applicability of its generic impact determination for spent fuel storage during license renewal, the NRC has determined that the petitioner's assertions do not present an adequate basis for the NRC to forego using a generic environmental analysis.

  7. Conclusion

    For the reasons described in Section II of this document, the NRC is denying the petition under 10 CFR 2.803. The petitioner did not present any information that would contradict conclusions reached by the Commission when it established or updated the license renewal rule, nor did the petitioner provide new and significant information to demonstrate that sufficient reason exists to revise the current regulations. The NRC elected not to request public comments on PRM-51-

    29 because it had sufficient information to make a determination.

    The events at the Fukushima Dai-ichi nuclear power plant have and will continue to inform improvements to the NRC's regulation of nuclear energy. Building upon the conclusions of the NTTF, the NRC is actively implementing significant enhancements through orders, rulemaking, and other regulatory initiatives. With regard to the petitioner's arguments that the events in Japan demonstrate that post-9/11 enhancements that enable the recovery of lost cooling water in SFPs will be ineffective, the petitioner did not provide sufficient information to support this claim, especially in light of the Commission's experiences and other studies noted previously.

    Therefore, the NRC denies the petitioner's request to revise regulations that make generic determinations about the environmental impacts of onsite spent fuel storage in license renewal environmental reviews.

  8. Availability of Documents

    The documents identified in the following table are available to interested persons as indicated. For more information on accessing ADAMS, see the ADDRESSES section of this document.

    ------------------------------------------------------------------------

    ADAMS Accession Number/

    Document Federal Register Citation/

    URL

    ------------------------------------------------------------------------

    CLI-11-05, Union Electric Company d/b/a http://www.nrc.gov/reading-

    Ameren Missouri (Callaway Plant, Unit 2), rm/doc-collections/

    September 9, 2011. commission/orders/2011/

    2011-05cli.pdf.

    CLI-99-22, Hydro Resources, Inc., July 23, http://www.nrc.gov/reading-

    1999. rm/doc-collections/

    commission/orders/1999/

    1999-022cli.pdf.

    COMSECY-13-0030, ``Staff Evaluation and ML13329A918.

    Recommendation for Japan Lessons Learned

    Tier 3 Issue on Expedited Transfer of

    Spent Fuel,'' November 12, 2013.

    Declaration of Dr. Gordon R. Thompson in ML111530345.

    Support of Commonwealth of Massachusetts'

    Contention and Related Petitions and

    Motions, June 1, 2011.

    Documentation of Evolution of Security ML092990438.

    Requirements at Commercial Nuclear Power

    Plants with Respect to Mitigation Measures

    for Large Fires and Explosions, February

    4, 2010.

    Federal Register notice--Continued Storage 79 FR 56238.

    of Spent Nuclear Fuel, September 19, 2014.

    Federal Register notice--Environmental 61 FR 28467.

    Review for Renewal of Nuclear Power Plant

    Operating Licenses Final Rule, June 5,

    1996.

    Federal Register notice--License Renewal of 78 FR 37325.

    Nuclear Power Plants; Generic

    Environmental Impact Statement and

    Standard Review Plans for Environmental

    Reviews, Issuance of NUREG-1437 and NUREG-

    1555, June 20, 2013.

    Federal Register notice--PRM-51-10, NRC 73 FR 46204.

    denial of Petition for Rulemaking, August

    8, 2008.

    Federal Register notice--PRM-51-29, 77 FR 75065.

    Commonwealth of Massachusetts, Notice of

    Receipt, December 19, 2012.

    Page 53272

    Federal Register notice--PRM-51-29, 77 FR 76952.

    Commonwealth of Massachusetts,

    Supplemental Information, December 31,

    2012.

    Federal Register notice--Revisions to 78 FR 37282.

    Environmental Review of Renewal of Nuclear

    Power Plant Operating Licenses Final Rule,

    June 20, 2013.

    Generic Environmental Impact Statement for ML13107A023.

    License Renewal of Nuclear Plants, NUREG-

    1437, Revision 1 (Volumes 1-3), June 21,

    2013.

    LBP-11-35, Memorandum and Order, denial of ML11332A152.

    waiver in Pilgrim adjudicatory proceeding,

    December 13, 2011.

    NEI 06-12, ``B.5.b Phases 2 & 3 Submittal ML070090060.

    Guideline, Revision 2,'' Project 689,

    December 14, 2006.

    NRC Overview of the Structural Integrity of ML14111A099.

    the Spent Fuel Pool at Fukushima Dai-ichi,

    Unit 4, April 25, 2014.

    NUREG-1353, ``Regulatory Analysis for the ML082330232.

    Resolution of Generic Issue 82, `Beyond

    Design Basis Accidents in Spent Fuel

    Pools,' '' April 30, 1989.

    NUREG-1437, ``Generic Environmental Impact ML13107A023.

    Statement for License Renewal of Nuclear

    Plants'' (2013 GEIS), June 20, 2013.

    NUREG-1437, ``Generic Environmental Impact ML040690705, ML040690738.

    Statement for License Renewal of Nuclear

    Plants'' (1996 GEIS; Volumes 1 and 2), May

    31, 1996.

    NUREG-1738, ``Technical Study of Spent Fuel ML010430066.

    Pool Accident Risk at Decommissioning

    Nuclear Power Plants,'' S102686, February

    28, 2001.

    NUREG-2157, ``Generic Environmental Impact ML14196A105, ML14196A107.

    Statement for Continued Storage of Spent

    Nuclear Fuel''.

    NUREG-2161, ``Consequence Study of a Beyond- ML14255A365.

    Design-Basis Earthquake Affecting the

    Spent Fuel Pool for a U.S. Mark I Boiling-

    Water Reactor'' (Spent Fuel Pool Study),

    October 9, 2013.

    Order EA-12-049, NRC Order on Mitigating ML12054A735.

    Strategies, March 12, 2012.

    Order EA-12-051, NRC Order on Spent Fuel ML12056A044.

    Pool Instrumentation, March 12, 2012.

    Order EA-13-109, NRC Order on Severe ML13143A321.

    Accident Capable Hardened Vents, June 6,

    2013.

    PRM-51-10, Commonwealth of Massachusetts, ML062640409.

    August 25, 2006.

    PRM-51-29, from Mathew Brock, Commonwealth ML12254A005.

    Of Mass. Petition for Waiver of C.F.R.

    Part 51 Subpart A, Appendix B or In

    Alternative Petition For Rulemaking to

    Rescind Regulations Excluding

    Consideration Of Spent Fuel Storage

    Impacts, June 2, 2011.

    Regulatory Guide 4.2, Supplement 1, ML13067A354.

    Revision 1, ``Preparation of Environmental

    Reports for Nuclear Power Plant License

    Renewal Applications,'' June 20, 2013.

    Report of Japanese Government to the IAEA http://www.kantei.go.jp/

    Ministerial Conference on Nuclear Safety-- foreign/kan/topics/201106/

    The Accident at TEPCO's Fukushima Nuclear iaea_houkokusho_e.html.

    Power Stations, June 2011.

    Sandia Letter Report, Revision 2, ML120970086.

    Mitigation of Spent Fuel Pool Loss-of-

    Coolant Inventory Accidents And Extension

    of Reference Plant Analyses to Other Spent

    Fuel Pools, November 30, 2006.

    Sandia Report: MELCOR 1.8.5 Separate Effect ML062290362.

    Analysis of Spent Fuel Assembly Accident

    Response, June 30, 2003.

    SECY-04-0191, ``Withholding Sensitive ML042310663.

    Unclassified Information Concerning

    Nuclear Power Reactors From Public

    Disclosure,'' October 19, 2004.

    SECY-11-0125, ``Issuance of Bulletin 2011- ML111250360.

    01, ``Mitigating Strategies,'' September

    12, 2011.

    SRM-COMSECY-13-0030, Staff Evaluation and ML14143A360.

    Recommendation for Japan Lessons-Learned

    Tier 3 Issue on Expedited Transfer of

    Spent Fuel, May 23, 2014.

    The Thompson Report, ``New And Significant ML12094A183.

    Information From The Fukushima Daiichi

    Accident In The Context Of Future

    Operation Of The Pilgrim Nuclear Power

    Plant,'' June 1, 2011.

    ------------------------------------------------------------------------

    Dated at Rockville, Maryland, this 25th day of August, 2015.

    For the Nuclear Regulatory Commission.

    Annette L. Vietti-Cook,

    Secretary of the Commission.

    FR Doc. 2015-21834 Filed 9-2-15; 8:45 am