(1) Applicability.

    (a)310 CMR 7.12 applies to any owner/operator of a facility if such facility meets any of the criteria in 310 CMR 7.12(1)(a)1. through 11. 1. Has a facility-wide maximum energy input capacity in BTU/hour from fuel utilization facilities equal to or greater than the following size thresholds
    a. All Fuels 40,000,000;
    b. Residual Fuel Oil 10,000,000;
    c. Solid Fuel 3,000,000;
    d. Used Oil Fuel 3,000,000; or
    e. Landfill Gas 3,000,000.
    2. Has a maximum energy input capacity in Btu/hour from any fuel utilization facility emission unit that combusts natural gas, propane, butane, or distillate oil equal to or greater than the 10,000,000 Btu/hour. 3. Has non-combustion federal potential1 to emit (facility-wide) equal to or greater than
    a. Particulate Matter two tons per year;
    b. Oxides of Sulfur 2.5 tons per year;
    c. Organic Material ten tons per year;
    d. Nitrogen Dioxide 4.4 tons per year; or
    e. Hazardous Air Pollutants ten tons of any individual HAP per year or 25 tons of total HAPs per year.
    4. Is or contains a hazardous waste incinerator, regardless of size. 5. Is or...