Airworthiness directives: CENTRAIR 101,

[Federal Register: December 13, 2004 (Volume 69, Number 238)]

[Proposed Rules]

[Page 72136-72138]

From the Federal Register Online via GPO Access [wais.access.gpo.gov]

[DOCID:fr13de04-15]

DEPARTMENT OF TRANSPORTATION

Federal Aviation Administration

14 CFR Part 39

[Docket No. FAA-2004-19616; Directorate Identifier 2004-CE-38-AD]

RIN 2120-AA64

Airworthiness Directives; CENTRAIR 101 Series Gliders

AGENCY: Federal Aviation Administration (FAA), DOT.

ACTION: Notice of proposed rulemaking (NPRM).

SUMMARY: The FAA proposes to adopt a new airworthiness directive (AD) for all CENTRAIR 101 series gliders with other than elevator or aileron part number (P/N) SY991A hinge pins installed. This proposed AD would require you to replace any installed elevator or aileron hinge pins that are not P/N SY991A hinge pins with P/N SY991A pins. This proposed AD results from mandatory continuing airworthiness information (MCAI) issued by the airworthiness authority for France. We are issuing this proposed AD to replace incorrectly heat-treated elevator or aileron hinge pins, which could result in failure of the elevator or ailerons. Such failure during takeoff, landing, or flight operations could lead to loss of glider control.

DATES: We must receive any comments on this proposed AD by January 14, 2005.

ADDRESSES: Use one of the following to submit comments on this proposed AD:

DOT Docket Web site: Go to http: //dms.dot.gov and follow the instructions for sending your comments electronically.

Government-wide rulemaking Web site: Go to http://www.regulations.gov and follow the instructions for sending your

comments electronically.

Mail: Docket Management Facility; U.S. Department of Transportation, 400 Seventh Street, SW., Nassif Building, Room PL-401, Washington, DC 20590-001.

Fax: 1-202-493-2251.

Hand Delivery: Room PL-401 on the plaza level of the Nassif Building, 400 Seventh Street, SW., Washington, DC, between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays.

To get the service information identified in this proposed AD, contact CENTRAIR, Aerodome B.P.N. 44, 36300 Le Blanc, France; telephone: 02.54.37.07.96; facsimile: 02.54.37.48.64.

To view the comments to this proposed AD, go to http://dms.dot.gov.

This is docket number FAA-2004-19616.

FOR FURTHER INFORMATION CONTACT: Greg Davison, Aerospace Engineer, FAA, Small Airplane Directorate, 901 Locust, Room 301, Kansas City, Missouri 64106; telephone: (816) 329-4130; facsimile: (816) 329-4090.

SUPPLEMENTARY INFORMATION:

Comments Invited

How do I comment on this proposed AD? We invite you to submit any written relevant data, views, or arguments regarding this proposal. Send your comments to an address listed under ADDRESSES. Include the docket number, ``FAA-2004-19616; Directorate Identifier 2004-CE-38-AD'' at the beginning of your comments. We will post all comments we receive, without change, to http://dms.dot.gov, including any personal

information you provide. We will also post a report summarizing each substantive verbal contact with FAA personnel concerning this proposed rulemaking. Using the search function of our docket Web site, anyone can find and read the comments received into any of our dockets, including the name of the individual who sent the comment (or signed the comment on behalf of an association, business, labor union, etc.). This is docket number FAA-2004-19616. You may review the DOT's complete Privacy Act Statement in the Federal Register published on April 11, 2000 (65 FR 19477-78) or you may visit http://dms.dot.gov.

Are there any specific portions of this proposed AD I should pay attention to? We specifically invite comments on the overall regulatory, economic, environmental, and energy aspects of this proposed AD. If you contact us through a nonwritten communication and that contact relates to a substantive part of this proposed AD, we will summarize the contact and place the summary in the docket. We will consider all comments received by the closing date and may amend this proposed AD in light of those comments and contacts.

[[Page 72137]]

Docket Information

Where can I go to view the docket information? You may view the AD docket that contains the proposal, any comments received, and any final disposition in person at the DMS Docket Offices between 9 a.m. and 5 p.m. (eastern standard time), Monday through Friday, except Federal holidays. The Docket Office (telephone 1-800-647-5227) is located on the plaza level of the Department of Transportation NASSIF Building at the street address stated in ADDRESSES. You may also view the AD docket on the Internet at http://dms.dot.gov. The comments will be available

in the AD docket shortly after the DMS receives them.

Discussion

What events have caused this proposed AD? The Direction G[eacute]n[eacute]rale de l'Aviation Civile (DGAC), which is the airworthiness authority for France, recently notified FAA that an unsafe condition may exist on all CENTRAIR 101 series gliders. The DGAC reports occurrences of improperly heat-treated aileron and elevator hinge pins installed on the CENTRAIR 101 series gliders. Incorrectly heat-treated elevator or aileron hinge pins could result in longitudinal cracks that cause failure of the elevator or ailerons. CENTRAIR has made available new hinge pins (part number (P/N) SY991A) to replace any incorrectly heat-treated elevator or aileron hinge pins or hinge pins with longitudinal cracks.

What is the potential impact if FAA took no action? Failure of the elevator or ailerons during takeoff, landing, or flight operations could lead to loss of glider control.

Is there service information that applies to this subject? CENTRAIR has issued Soci[eacute]t[eacute] Nouvelle Centrair Service Bulletin No. 101-22, dated March 13, 2001.

What are the provisions of this service information? The service bulletin includes procedures for:

--Immediately inspecting (visually and with dye penetrant) the aileron and elevator hinge pins for cracks; --Immediately replacing any hinge pins found with longitudinal cracks as a result of the above inspection; and --Eventually replacing any installed elevator or aileron hinge pins that are not P/N SY991A hinge pins with P/N SY991A pins.

What action did the DGAC take? The DGAC classified this service bulletin as mandatory and issued French AD Number 2001-247(A), dated June 27, 2001, to ensure the continued airworthiness of these gliders in France.

Did the DGAC inform the United States under the bilateral airworthiness agreement? These CENTRAIR 101 series gliders are manufactured in France and are type-certificated for operation in the United States under the provisions of section 21.29 of the Federal Aviation Regulations (14 CFR 21.29) and the applicable bilateral airworthiness agreement.

Under this bilateral airworthiness agreement, the DGAC has kept us informed of the situation described above.

FAA's Determination and Requirements of This Proposed AD

What has FAA decided? We have examined the DGAC's findings, reviewed all available information, and determined that AD action is necessary for products of this type design that are certificated for operation in the United States.

Since the unsafe condition described previously is likely to exist or develop on other CENTRAIR 101 series gliders of the same type design that are registered in the United States, we are proposing AD action to replace incorrectly heat-treated elevator or aileron hinge pins, which could result in failure of the elevator or ailerons. Such failure during takeoff, landing, or flight operations could lead to loss of glider control.

What would this proposed AD require? This proposed AD would require you to replace with P/N SY991A hinge pins any installed elevator or aileron hinge pins that are not P/N SY991A hinge pins.

How does the revision to 14 CFR part 39 affect this proposed AD? On July 10, 2002, we published a new version of 14 CFR part 39 (67 FR 47997, July 22, 2002), which governs FAA's AD system. This regulation now includes material that relates to altered products, special flight permits, and alternative methods of compliance. This material previously was included in each individual AD. Since this material is included in 14 CFR part 39, we will not include it in future AD actions.

Costs of Compliance

How many gliders would this proposed AD impact? We estimate that this proposed AD affects 57 gliders in the U.S. registry.

What would be the cost impact of this proposed AD on owners/ operators of the affected gliders? We estimate the following costs to do this proposed elevator and aileron hinge pin replacement. We have no way of determining the number of gliders that may need this hinge pin replacement. However, we have presented the costs to reflect all 57 gliders needing the mandatory replacement:

Total cost Labor cost

Parts cost

per

Total cost on U.S. operators

4 workhours x $65 per hour = $260.........

$1

$261 $261 x 57 = $14,877

Regulatory Findings

Would this proposed AD impact various entities? We have determined that this proposed AD would not have federalism implications under Executive Order 13132. This proposed AD would not have a substantial direct effect on the States, on the relationship between the National Government and the States, or on the distribution of power and responsibilities among the various levels of government.

Would this proposed AD involve a significant rule or regulatory action? For the reasons discussed above, I certify that this proposed AD:

  1. Is not a ``significant regulatory action'' under Executive Order 12866;

  2. Is not a ``significant rule'' under the DOT Regulatory Policies and Procedures (44 FR 11034, February 26, 1979); and

  3. Will not have a significant economic impact, positive or negative, on a substantial number of small entities under the criteria of the Regulatory Flexibility Act.

    We prepared a summary of the costs to comply with this proposed AD and placed it in the AD Docket. You may get a copy of this summary by sending a request to us at the address listed under ADDRESSES. Include ``AD Docket FAA-2004-19616; Directorate Identifier 2004-CE-38-AD'' in your request.

    This proposed rulemaking is promulgated under the authority in subtitle VII, part A, subpart III, section 44701, General requirements. Under that section, the FAA is charged with prescribing minimum standards required in the interest of safety for the design of aircraft. This proposed regulation is within the scope of that authority since it corrects an unsafe

    [[Page 72138]]

    condition in the design of the aircraft caused by incorrectly heat- treated elevator or aileron hinge pins, which could result in failure of the elevator or ailerons. Such failure during takeoff, landing, or flight operations could lead to loss of glider control.

    List of Subjects in 14 CFR Part 39

    Air transportation, Aircraft, Aviation safety, Safety.

    The Proposed Amendment

    Accordingly, under the authority delegated to me by the Administrator, the Federal Aviation Administration proposes to amend 14 CFR part 39 as follows:

    PART 39--AIRWORTHINESS DIRECTIVES

  4. The authority citation for part 39 continues to read as follows:

    Authority: 49 U.S.C. 106(g), 40113, 44701.

    Sec. 39.13 [Amended]

  5. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD):

    CENTRAIR: Docket No. FAA-2004-19616; Directorate Identifier 2004-CE- 38-AD

    When Is the Last Date I Can Submit Comments on This Proposed AD?

    (a) We must receive comments on this proposed airworthiness directive (AD) by January 14, 2005.

    What Other ADs Are Affected by This Action?

    (b) None.

    What Gliders Are Affected by This AD?

    (c) This AD affects Models 101, 101A, 101AP, and 101P gliders, all serial numbers, without elevator and aileron part number SY991A hinge pins installed, certificated in any category.

    What Is the Unsafe Condition Presented in This AD?

    (d) This AD is the result of mandatory continuing airworthiness information (MCAI) issued by the airworthiness authority for France. The actions specified in this AD are intended to replace incorrectly heat-treated elevator or aileron hinge pins, which could result in failure of the elevator or ailerons. Such failure during takeoff, landing, or flight operations could lead to loss of glider control.

    What Must I Do To Address This Problem?

    (e) To address this problem, you must do the following:

    Actions

    Compliance

    Procedures

    (1) Replace any installed

    Within the next 25 Follow elevator and aileron hinge pins hours time-in- Soci[eacute]t[eac that are not part number (P/N) service (TIS) ute] Nouvelle SY991A hinge pins with P/N

    after the

    Centrair Service SY991A hinge pins.

    effective date of Bulletin No. 101- this AD, unless 22, dated March already done. 13, 2001. (2) Do not install any elevator As of the

    Not Applicable. and aileron hinge pins that are effective date of not P/N SY991A hinge pins as this AD. specified in paragraph (e)(1) of this AD.

    May I Request an Alternative Method of Compliance?

    (f) You may request a different method of compliance or a different compliance time for this AD by following the procedures in 14 CFR 39.19. Unless FAA authorizes otherwise, send your request to your principal inspector. The principal inspector may add comments and will send your request to the Manager, Standards Office, Small Airplane Directorate, FAA. For information on any already approved alternative methods of compliance, contact Greg Davison, Aerospace Engineer, FAA, Small Airplane Directorate, 901 Locust, Room 301, Kansas City, Missouri 64106; telephone: (816) 329-4130; facsimile: (816) 329-4090.

    Is There Other Information That Relates to This Subject?

    (g) French AD Number 2001-247(A), dated June 27, 2001, also addresses the subject of this AD.

    May I Get Copies of the Documents Referenced in This AD?

    (h) To get copies of the documents referenced in this AD, contact CENTRAIR, Aerodome B.P.N. 44, 36300 Le Blanc, France; telephone: 02.54.37.07.96; facsimile: 02.54.37.48.64. To view the AD docket, go to the Docket Management Facility; U.S. Department of Transportation, 400 Seventh Street, SW., Nassif Building, Room PL- 401, Washington, DC, or on the Internet at http://dms.dot.gov. This

    is docket number FAA-2004-19616.

    Issued in Kansas City, Missouri, on December 6, 2004. Scott L. Sedgwick, Acting Manager, Small Airplane Directorate, Aircraft Certification Service.

    [FR Doc. 04-27196 Filed 12-10-04; 8:45 am]

    BILLING CODE 4910-13-P

VLEX uses login cookies to provide you with a better browsing experience. If you click on 'Accept' or continue browsing this site we consider that you accept our cookie policy. ACCEPT