Corded Window Coverings; Request for Comments and Information

Federal Register, Volume 80 Issue 11 (Friday, January 16, 2015)

Federal Register Volume 80, Number 11 (Friday, January 16, 2015)

Proposed Rules

Pages 2327-2350

From the Federal Register Online via the Government Printing Office www.gpo.gov

FR Doc No: 2015-00566

Page 2327

CONSUMER PRODUCT SAFETY COMMISSION

16 CFR Chapter II

CPSC Docket No. CPSC-2013-0028

Corded Window Coverings; Request for Comments and Information

AGENCY: Consumer Product Safety Commission.

ACTION: Advance notice of proposed rulemaking.

-----------------------------------------------------------------------

SUMMARY: The Consumer Product Safety Commission (the Commission or CPSC) has reason to believe that certain cords on window coverings may present an unreasonable risk of injury to young children. This advance notice of proposed rulemaking (ANPR) initiates a rulemaking proceeding under the Consumer Product Safety Act (CPSA). We invite comments concerning the risk of injury associated with corded window coverings, the regulatory alternatives discussed in this notice, the costs to achieve each regulatory alternative, the effect of each alternative on the safety, cost, utility, and availability of window coverings, and other possible ways to address the risk of strangulation posed to young children by window covering cords. We also invite interested persons to submit an existing standard or a statement of intent to modify or develop a voluntary standard to address the risk of injury described in this notice.

DATES: Written comments in response to this notice must be received by March 17, 2015.

ADDRESSES: You may submit comments, identified by Docket No. CPSC-2013-

0028, by any of the following methods:

Electronic Submissions

Submit electronic comments in the following way:

Federal eRulemaking Portal: http://www.regulations.gov. Follow the instructions for submitting comments.

The Commission does not accept comments submitted by electronic mail (email), except through www.regulations.gov. The Commission encourages you to submit electronic comments by using the Federal eRulemaking Portal as described above.

Written Submissions

Submit written submissions in the following way:

Mail/Hand delivery/Courier to: Office of the Secretary, Consumer Product Safety Commission, Room 820, 4330 East West Highway, Bethesda, MD 20814; (301) 504-7923.

Instructions: All submissions received must include the agency name and docket number for this rulemaking. All comments received may be posted without change, including any personal identifiers, contact information, or other personal information provided, to: http://www.regulations.gov. Do not submit confidential business information, trade secret information, or other sensitive or protected information electronically. Such information should be submitted in writing.

Docket: For access to the docket to read background documents or comments received, go to: http://www.regulations.gov.

FOR FURTHER INFORMATION CONTACT: Rana Balci-Sinha, Project Manager, Directorate for Engineering Sciences, Consumer Product Safety Commission, National Product Testing and Evaluation Center, 5 Research Place, Rockville, MD 20850; 301-987-2584; rbalcisinha@cpsc.gov.

SUPPLEMENTARY INFORMATION:

  1. Background

    The purpose of this ANPR is to collect information related to a potential mandatory rule to address the risk of strangulation to young children on window covering cords. On October 8, 2014, the Commission granted a petition to initiate a rulemaking to develop a mandatory safety standard for window coverings. The petition sought to prohibit window covering cords when a feasible cordless alternative exists. When a feasible cordless alternative does not exist, the petition requested that all window covering cords be made inaccessible by using passive guarding devices. The Commission granted the petition and directed staff to prepare this ANPR seeking information and comment on regulatory options for a mandatory rule to address the risk of strangulation to young children on window covering cords.

    This ANPR is based on information from staff's December 31, 2014 Briefing Memorandum on Recommended Advance Notice of Proposed Rulemaking for Corded Window Coverings (ANPR Briefing Memorandum), available at http://www.cpsc.gov/Global/Newsroom/FOIA/CommissionBriefingPackages/2015/Corded-Window-Coverings-Advance-Notice-of-Proposed-Rulemaking.pdf, as well as CPSC staff's October 1, 2014 Staff Briefing Package in Response to the Petition CP 13-2, Requesting Mandatory Safety Standards for Window Coverings (Petition Briefing Package), available at: http://www.cpsc.gov/Global/Newsroom/FOIA/CommissionBriefingPackages/2015/PetitionRequestingMandatoryStandardforCordedWindowCoverings.pdf.

    Based on CPSC's incident data, the Commission believes that certain window covering cords may present an unreasonable risk of injury, specifically strangulation, to young children. The Commission is aware of 184 reported fatal strangulations and 101 reported nonfatal strangulations from 1996 through 2012 involving window covering cords among children 8 years and younger. Petition Briefing Package, Tab B. Using separate data from the National Center for Health Statistics (NCHS) and a CPSC study, CPSC estimates that on average, at least 11 fatal strangulations related to window covering cords occurred per year in the United States from 1999 through 2010, among children under 5 years old. CPSC finds no observable trend in the data. Id.

    CPSC evaluated the risk of a fatal or nonfatal strangulation to children involving window covering cords. Based on various CPSC data sources (e.g., newspaper clippings, consumer complaints, death certificates purchased from states, medical examiners' reports, and in-

    depth investigation (IDI) reports by CPSC staff), from 1996 through 2012, CPSC found, on average, about 11 reported fatal strangulations, and on average, about six reported nonfatal strangulation incidents per year for children 8 years and younger. Id.

    Tab E of staff's Petition Briefing Package analyzed the current voluntary standard for window coverings, ANSI/WCMA A100.1-2014, American National Standard for Safety of Corded

    Page 2328

    Window Covering Products (ANSI/WCMA standard or voluntary standard). CPSC engineering staff found that the current version of the ANSI/WCMA standard would not effectively address 57 percent of the 249 window covering cord incidents investigated by CPSC staff. Two types of cords on window coverings continue to present a hazard to children: Pull cords and continuous loops.

    The Commission invites the public to review the information and ideas presented in this ANPR and to submit information and comments that would assist the Commission as it considers regulatory alternatives to reduce the strangulation risk to young children associated with corded window covering products.

  2. Window Covering Products

    Window coverings comprise a wide range of products, including shades, blinds, curtains, and draperies. In general terms, ``hard'' window coverings, composed of slats or vanes, are considered blinds; and ``soft'' window coverings that contain a continuous roll of material are considered shades. Both blinds and shades may have inner cords that cause a motion, such as raising, lowering, traversing, or rotating the window covering to achieve the desired level of light control. Curtains and draperies do not contain inner cords but may be operated by a continuous loop cord or beaded chain. The cord or loop that is manipulated by the consumer to operate the window covering is called an ``operating cord'' and may be a pull cord (single cord or multiple cords) or continuous loops. Cordless window coverings are products designed to function without an operating cord but may contain inner cords. Petition Briefing Package, Briefing Memorandum at 9.

    1. Common Window Covering Products

      Following is a description of the most common window covering products and the types of cords associated with incidents for each window covering product. Cord types are based on CPSC's review of the 249 IDIs completed by staff on window covering incidents. Petition Briefing Package, Briefing Memorandum Appendix, and Tab B at 83-84.

      1. Horizontal blind (Figure 1): Horizontal blinds are made using horizontal slats. Slats vary in their length and width and are manufactured using metal, vinyl, wood, fabric, and other materials. Horizontal blinds are typically raised and lowered using pull cords. Pull cords are part of the inner cords that users interact with to raise or lower the blind. Inner cords are attached to the bottom rail and threaded through the horizontal slats to raise and lower them, as well as to adjust the slats for lighting. Slats can be tilted with various mechanisms, including tilt cords, a tilt wand, or in the case of a blind with no operating cords, by using the bottom rail. Cords associated with horizontal blind incidents include: continuous loop cord/beaded-chain (free-standing, i.e., not mounted on a tension device), inner cord, pull cord (with loops or long cords), and tilt cord.

      GRAPHIC TIFF OMITTED TP16JA15.000

      2. Cellular shade (Figure 2): Cellular shades are made of multiple layers of material that are formed into tubes or cells in a horizontal orientation. Cellular shades, often referred to as honeycomb shades, are constructed so that an air pocket, which mimics the shape of a bee's honeycomb, is formed in the center of the shade. Cellular shades are typically raised and lowered using an operating cord. Inner cords that assist in raising and lowering the blind are between the layers of material and are visible from the side openings only. Cords associated with cellular shade incidents include: continuous loop cord/beaded-

      chain (free-standing) and pull cord (with loops, cord connectors, or long cords).

      Page 2329

      GRAPHIC TIFF OMITTED TP16JA15.001

      3. Pleated shade (Figure 3): Pleated shades are made of pleated or folded material in a horizontal orientation. The pleated material can be raised and lowered similar to cellular shades. Unlike cellular shades, pleated shades do not have an air pocket. Cords associated with pleated shade incidents include: Continuous loop cord/beaded-chain (free-standing) and pull cord (with loops or long cords).

      GRAPHIC TIFF OMITTED TP16JA15.002

      4. Roller shade (Figure 4): Roller shades are comprised of a roller, a means of supporting the roller, and flexible sheets of material attached to the roller. When a roller shade is raised, the material is gathered on the roller located at the top of the shade. Cords associated with roller shade incidents include: Continuous loop cord/beaded-chain (free-standing).

      Page 2330

      GRAPHIC TIFF OMITTED TP16JA15.003

      5. Roll-up blind (Figure 5): Roll-up blinds are made of flexible material, which rolls up from the bottom of the blind when the blind is raised. Roll-up blinds are typically raised and lowered using pull cords. Cords associated with roll-up blind incidents include: Pull cord (with loops or long cords) and lifting loop (wraps around the bottom of the product and enables the shade to roll up from bottom to top.).

      GRAPHIC TIFF OMITTED TP16JA15.004

      6. Roman shade (Figure 6): Roman shades are made of fabric or other material that is suspended from a head rail. As the shade is raised, the material gathers from the bottom upward, toward the head rail. Cords associated with Roman shade incidents include: continuous loop cord/beaded-chain (free-standing), inner cords, and pull cord (with loops or long cords).

      GRAPHIC TIFF OMITTED TP16JA15.005

      Page 2331

      7. Vertical blind (Figure 7): Vertical blinds are made using slats in a vertical orientation that can be stacked to one or both sides of the head rail. The head rail houses mechanisms that allow slats to traverse or rotate or both. Cords associated with vertical blind incidents include: Continuous loop cord/beaded-chain (free-standing).

      GRAPHIC TIFF OMITTED TP16JA15.006

      8. Drapery/Curtain (Figure 8): Draperies and curtains are usually made of a fabric material that hangs in a window or other opening (e.g., sliding door). Cords can sometimes be used to open and close draperies and curtains. Cords associated with drapery and curtain incidents include: Continuous loop cord/beaded-chain (free-standing).

      GRAPHIC TIFF OMITTED TP16JA15.007

    2. Window Covering Market

      Based on 2011 data, more than 350 manufacturers and more than 1,800 retailers of window coverings operate in the United States. Petition Briefing Package, Tab G. Three manufacturers reportedly accounted for almost 70 percent of dollar sales in the U.S. window coverings market in 2008. Retail prices for corded window coverings have a wide range. The type of material, brands, and operating mechanisms affect the price. Average prices for window coverings range from about $50 to $440 for shades and from about $10 to $360 for blinds. Retail prices for extremely large and custom-made window coverings can be as high as $3,000.

      The Commission obtained window covering market information from a study conducted by the consulting firm D&R International (D&R, 2013).\1\ The Window Covering Manufacturers Association (WCMA), the organization that developed the existing voluntary standard, engaged D&R to conduct the study. D&R received funding for the study from WCMA and the U.S. Department of Energy (DOE), through Lawrence Berkeley National Laboratory (LBNL). Based on information from the D&R study, shipments of residential window coverings from manufacturers may have amounted to about 100 million to 150 million units in the United States in 2012. D&R based these estimates on information (including shipment, pricing, retail and manufacturing data) provided by WCMA members, U.S. Census Bureau reports of vinyl blind imports, and data collected from a WCMA-funded Internet survey of U.S. households, which D&R also conducted as part of the study. WCMA participated in designing and implementing the Internet survey. D&R developed a research plan in consultation with WCMA, with input from LBNL. DOE, through LBNL, provided funding to analyze the Internet survey and prepare the report.\2\ Augmenting the D&R estimates with U.S. housing statistics, more than 1 billion window coverings may be in use

      Page 2332

      in U.S. homes. Petition Briefing Package, Tab G at 148-152.

      ---------------------------------------------------------------------------

      \1\ D&R International, Ltd. (September 2013). Residential windows and window coverings: A detailed view of the installed base and user behavior (DOE/EE-0965). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Washington DC. September, 2013. Available at: http://energy.gov/eere/buildings/downloads/residential-windows-and-window-coverings-detailed-view-installed-base-and.

      \2\ Ibid.

      ---------------------------------------------------------------------------

      The Commission does not have precise information on sales of cordless window coverings (or window coverings with inaccessible cords), but based on CPSC discussions with industry participants and review of a major retailer's Web site, sales of cordless window coverings may amount to as much as 25 percent of the market.

      CPSC compared the retail sales prices of cordless and corded products and found that manually operated cordless window coverings may cost about $15 to $130 more than similar corded window coverings. The observed prices of motor-operated window coverings are more than $100 higher than the prices of corded window coverings, and the price differences can exceed $300. Some wand-operated vertical blinds cost about the same as corded versions; others appear to cost about $10 more than corded vertical blinds. The Commission has insufficient information to determine how the costs or retail prices of safer window coverings will change over time. Id.

  3. The Risk of Injury

    1. Incident Data Overview

      CPSC estimates that a minimum of 11 fatal strangulations related to window covering cords, on average, occurred per year in the United States from 1999 through 2010, among children under 5 years old, based on National Center for Health Statistics (NCHS) data and a CPSC study.\3\ Petition Briefing Package, Tab B. Additionally, CPSC's emergency department-treated injury data (National Electronic Injury Surveillance System or NEISS) demonstrate that from 1996 through 2012, an estimated 1,590 children received treatment for injuries resulting from entanglements on window covering cords based on NEISS data. Id. at 80-82.

      ---------------------------------------------------------------------------

      \3\ N. Marcy, G. Rutherford. ``Strangulations Involving Children Under 5 Years Old.'' U.S. Consumer Product Safety Commission, December 2002.

      ---------------------------------------------------------------------------

      CPSC also receives incident data through newspaper clippings, consumer complaints, death certificates purchased from states, medical examiners' reports, and IDI reports. Using data from these sources, CPSC found a total of 285 reported fatal and nonfatal strangulation incidents from January 1996 through December 2012 involving window coverings among children 8 years of age or younger. These 285 incidents do not constitute a statistical sample of known probability and do not necessarily include all window covering, cord-related strangulation incidents that occurred during that period. Given that these reports are anecdotal and reporting is incomplete, CPSC strongly discourages drawing any inferences based on the year-to-year increase or decrease shown in the reported data. Id.

      Of the 285 incidents, 184 resulted in a fatality. Among the nonfatal incidents, 19 involved hospitalizations (7 percent). The long-

      term outcomes of these 19 injuries varied from a scar around the neck, to quadriplegia, to permanent brain damage. In addition, 67 incidents (24 percent) involved less-severe injuries, some of which required medical treatment but not hospitalization. In the remaining 15 incidents (5 percent), a child became entangled in a window covering cord but was able to disentangle him or herself from the cord and escape injury.

      Of the 285 total reported incidents involving window covering cords, CPSC staff reviewed the completed IDIs for 249 incidents. Table 1 presents a breakdown of all 249 investigated incidents, by type of window coverings and type of cord.

      Table 1--Distribution of Investigated Incidents by Type of Window Covering and Associated Cord 1996-2012

      --------------------------------------------------------------------------------------------------------------------------------------------------------

      Continuous

      Pull cord loop cord/ Inner cord Lifting loop Tilt cord Unknown Total

      beaded-chain (percentage)

      --------------------------------------------------------------------------------------------------------------------------------------------------------

      Horizontal.............................. 90 3 23 .............. 2 13 131 (53%)

      Vertical................................ .............. 41 .............. .............. .............. 2 43 (17)

      Roman................................... 2 1 24 .............. .............. .............. 27 (11)

      Curtain/drapery......................... .............. 13 .............. .............. .............. 1 14 (6)

      Cellular................................ 5 5 .............. .............. .............. .............. 10 (4)

      Roller.................................. .............. 6 .............. .............. .............. .............. 6 (2)

      Roll-up................................. 2 .............. .............. 3 .............. .............. 5 (2)

      Unknown................................. 2 1 .............. .............. .............. 10 13 (5)

      ---------------------------------------------------------------------------------------------------------------

      Total............................... 101 70 47 3 2 26 249 (100)

      --------------------------------------------------------------------------------------------------------------------------------------------------------

      Source: CPSC In-Depth Investigation File (INDP).

      Of the 249 incidents investigated by CPSC staff, 170 involved a fatality. Ninety-two (54 percent) of these fatal incidents involved a horizontal blind, 36 (21 percent) involved a vertical blind, 14 (8 percent) involved a curtain/drapery, eight (5 percent) a Roman shade, five (3 percent) a cellular shade, four (2 percent) a roll-up shade, and two (1 percent) a roller shade. Staff was unable to identify the window covering type in 9 (5 percent) of the 170 fatalities. Id. at 84-

      85.

    2. Physiology of Strangulation and Associated Injuries

      Young children are at risk of strangulation on corded window coverings. Strangulation due to mechanical compression of the neck involves obstruction of the airway passage and occlusion of blood vessels in the neck. Petition Briefing Package, Tab C. Strangulation can occur when a child's head or neck becomes entangled in any position, even in situations where the body is fully or partially supported, in the event that a lateral pressure is sustained at a level resulting in vascular occlusion. Id. at 94.

      Strangulation can rapidly progress to anoxia, associated cardiac arrest, and death. Permanent, irreversible damage can occur if the delivery of oxygen to tissues is reduced. The severity of oxygen deprivation ultimately governs the victim's chance for survival or the degree of neurological damage. Neurological damage may range from amnesia, loss of cognitive abilities due to hypoxic-ischemic injury to the hippocampus, mobility limitations, and

      Page 2333

      loss of function, to long-term vegetative state. Experimental studies show that 2 kg (4.4 lbs.) of pressure on the neck may occlude the jugular vein \4\ and 3-5 kg (7-11 lbs.) may occlude the carotid artery.\5\ Minimal compression of any of these vessels can lead to unconsciousness within 15 seconds and death in 2 to 3 minutes (Digeronimo and Mayes, 1994; Hoff, 1978; lserson, 1984; Polson, 1973).\6\ The vagus nerve, responsible for maintaining a constant heart rate, is also located in the neck, in close proximity to the jugular vein and carotid artery. If the vagus nerve is compressed, cardiac arrest can result, due to mechanical stimulation of the carotid sinus-

      vagal reflex. Petition Briefing Package, Tab C at 94-95.

      ---------------------------------------------------------------------------

      \4\ Brouardel P. La pendaison, La strangulation, La suffocation, La submersion. JB Bailliere et fil, Paris, France, 1897; pp. 38-40.

      \5\ Ibid. and Polson CJ. Hanging In: Polson CJ and Gee DJ (eds.) Essentials of forensic medicine, Oxford England, 1973 371-404.

      \6\ Digeronimo RJ1, Mayes TC. Near-hanging injury in childhood: a literature review and report of three cases. Pediatr Emerg Care. 1994 Jun; 10(3):150-6; Hoff BH. Multiple organ failure after near-

      hanging. Crit Care Med 1978; 6:366-9. Howell MA; Iserson, K.V. Strangulation: A review of ligature, manual and postural neck compression injuries. Ann. Emerg. Med. 13:179-185, 1984; Polson CJ. Hanging In: Polson CJ and Gee DJ (eds.) Essentials of forensic medicine, Oxford England, 1973 371-404.

      ---------------------------------------------------------------------------

      The majority of incidents involving window covering cords resulted in death (184 of 285 incidents reviewed). Of the 19 incidents that required hospitalization, nine patients suffered severe neurological outcomes, such as cerebral edema, coma, loss of cognitive abilities, a loss of function or mobility, and quadriplegia. Some patients required intensive care, monitoring, lifelong care, and therapy. Four of the entanglement incidents occurred on the child's arm or wrist and did not involve the neck. In 78 incidents involving the neck that were reported as minor or no injury, the child was found entangled in a cord or with the cord wrapped around the neck. In some incidents, the cord was wrapped so tightly that the child turned blue and had red marks or rope burns visible on the neck. Three children suffered temporary airway obstruction and were subsequently taken to the hospital. If the child had not been released from the cord, all of these nonfatal incidents could have had a more serious and even fatal outcome. Id. at 95.

    3. Population at Risk of Strangulation

      Corded window covering incidents involve children from about 7 months to 8 years old. Petition Briefing Package, Tab C at 95. Incident data demonstrate that hazard scenarios involving window covering cords are consistent with child development milestones. Children go from total dependence on others to independence in their first 5 years of life. Petition Briefing Package, Tab D. Starting from around 3 months of age, children begin to grasp objects placed in their hands. By 6 months of age, most children master reaching and grasping objects within their reach. Children learn to stand by holding onto an object starting at around 8 months of age, and a month later, they can stand. At around 10 months of age, children learn to stand without holding on to an object. Between 12 to 18 months of age, children progress from walking, to running, to walking up stairs, to climbing. As children gain new skills (e.g., sitting, standing, walking, running, climbing), they want to use and perfect those skills.\7\ The window covering cord incident data show that children climbed on beds, chairs, tables, and other furniture to interact with the window coverings. In some incidents, children were reportedly imitating superheroes or using the beaded chains as necklaces. Petition Briefing Package, Tab D at 101-

      102.

      ---------------------------------------------------------------------------

      \7\ Frankenburg, W.K., Dodds, J., Archer, P. et al.: The DENVER II Technical Manual 1990, Denver Developmental Materials, Denver, Co.

      ---------------------------------------------------------------------------

      Parents are advised to encourage children to start taking care of themselves beginning at around age 2 years so that the children can learn independence and self-discovery. During these times of independence and exploration, children have less supervision. The degree of appropriate supervision is strongly linked to developmental level. Research shows that for preschool (birth to 4 years), constant supervision is required, except when children are in rooms in the home that are perceived as safe (living room/bedroom) or in rooms that are deemed fairly safe (bathroom/garage/kitchen).\8\ Children's bedrooms and living or play rooms are considered by caregivers to be the safest rooms in the home. A review of the incidents reported to CPSC shows that bedrooms, living rooms, family rooms, or TV rooms were the locations where most incidents occurred. These are rooms that caregivers perceive to be the safest rooms in the home, and thus, caregivers may be inclined to leave children alone in these rooms. Petition Briefing Package, Tab D at 102-103.

      ---------------------------------------------------------------------------

      \8\ Peterson, L., Ewigman, B., and Kivlahan, C., (1993) ``Judgments Regarding Appropriate Child Supervision to Prevent Injury: The Role of Environmental Risk and Child Age.'' Child Development, 64, 934-950.

      ---------------------------------------------------------------------------

      Research demonstrates that the more familiar caregivers are with a product, the lower their recognition is of the product's hazards.\9\ Increased familiarity, ease and frequency of use, and low price of a product reduce the likelihood that people will read warning labels. Consumers are highly familiar with window coverings and interact with window coverings daily. Even though no specific studies or surveys related to the use of safety devices for window coverings exist, research shows that the rate of compliance with instructions is lower when more effort and time (cost of compliance) are required to comply with the instructions.\10\

      ---------------------------------------------------------------------------

      \9\ Vredenburgh, A.G., & Zackowitz, I.B., (2006). Expectations. In M. S. Wogalter (Ed.), Handbook of warnings (pp. 345-354). Mahwah, NJ: Lawrence Erlbaum Associates.

      \10\ DeJoy, D.M., (1999). Attitudes and Beliefs. In M. S. Wogalter, D. M. DeJoy, & K. R. Laughery (Eds.), Warnings and risk communication (pp. 189-219). Philadelphia: Taylor & Francis.

      ---------------------------------------------------------------------------

      In some incidents, parents had seen the warning labels and were aware of the hazards of hanging cords and continuous loops. Parents used cord cleats, tied the cords together, or used other means to keep the cords out of reach of the child; however, the child was still able to access the cords and strangle. In other cases, parents did not use any safety devices. One reason for not using the safety devices is that the parents may have assumed the cords were not a problem because their child had not shown any interest in the window blind cords. In some incidents, safety devices, such as tie-down devices or cord cleats, were not used when the parents did not perceive a threat to the child. In a few cases, parents reported that that they had observed their child's interaction with cords but did not think the cords were a danger. Petition Briefing Package, Tab D at 103-105.

      The Commission concludes that if cords are accessible and hazardous, window coverings will present a risk of strangulation to young children. Children cannot be supervised 100 percent of the time, and they can strangle in a few minutes. Children will continue to explore their environment and interact with accessible window covering cords even when parents try to be conscientious and use safety devices on window coverings. Id. at 106.

    4. Hazard Scenarios Associated With Corded Window Covering Products

      Table 2 depicts the nine hazard scenarios CPSC staff found when reviewing 249 IDIs related to corded window covering incidents.

      BILLING CODE 6355-01-P

      Page 2334

      GRAPHIC TIFF OMITTED TP16JA15.008

      Page 2335

      GRAPHIC TIFF OMITTED TP16JA15.009

      Page 2336

      GRAPHIC TIFF OMITTED TP16JA15.010

      BILLING CODE 6355-01-C

  4. Efforts To Address the Hazard Associated With Corded Window Coverings

    1. Development of a Voluntary Standard

      1. Performance Requirements

      CPSC has been working with the window covering industry to address the hazards associated with corded window covering products for many years. Petition Briefing Package, Briefing Memorandum at 14-15, Table E, and Tab F. In 1995, CPSC staff began working with the WCMA on an ANSI/WCMA standard to address accessible cords on window coverings. WCMA published the first version of the ANSI/WCMA standard in 1996. The 1996 standard sought to prevent strangulation

      Page 2337

      incidents created by looped cords by requiring either: (a) Separate operating cords, or (b) a cord release device on multiple cords ending in one tassel. The standard also required a tension device that would hold the cord or bead loop taut when installed according to manufacturer's instructions.

      In 2001, CPSC staff sent a letter to the WCMA asking for revisions to the 1996 standard, including the addition of inner cord stops and the elimination of free-hanging cords or bead chains longer than the neck circumference of a fifth percentile 7- to 9-month-old child. In January 2002, CPSC staff sent a similar request by letter to WCMA. In August 2002, the published ANSI/WCMA standard required inner cord stops. In 2007, the published ANSI/WCMA standard required that tension devices partially limit the consumer's ability to control the blind if the tension device is not properly installed.

      In 2009, WCMA published a provisional voluntary standard specifying descriptive requirements for Roman shades. CPSC staff sent a letter to the WCMA underscoring that the descriptive requirements still allowed inner cords to be accessible. In September 2010, WCMA published a stronger performance-based standard addressing Roman shade inner cords as another provisional standard. In November 2010, CPSC held a public meeting and WCMA announced that WCMA would establish a steering committee to oversee the activities of six task groups, including one intended for pull cords and another for continuous loops. At the CPSC public meeting, WCMA reiterated its intent to minimize the risks associated with pull cords and continuous loops and to draft revisions to the voluntary standard for balloting by the end of October 2011.

      On December 20, 2011, the WCMA balloted proposed revisions to the voluntary standard. On February 6, 2012, staff sent WCMA a letter providing comments on the proposed revision. In these comments, CPSC staff reiterated that the hazardous loop determination should be made for all cords and that the length of an accessible operating cord should not be longer than the neck circumference of the youngest child at risk. In addition, staff raised concerns about the inability of tension devices to eliminate effectively or reduce significantly the risk of strangulation under certain foreseeable-use conditions.

      In November 2012, the WCMA announced the approval of the 2012 version of the ANSI/WCMA standard, which includes: (1) Requirements for durability and performance testing of the tension/hold down devices, including new requirements for anchoring; (2) specific installation instructions and warnings; (3) new requirements for products that rely on ``wide lift bands'' to raise and lower window coverings; (4) requirements for a warning label and pictograms on the outside of stock packaging and merchandising materials for corded products; and (5) expanded testing requirements for cord accessibility, hazardous loop testing, roll-up style shade performance, and durability testing of all safety devices.

      WCMA approved a revised ANSI/WCMA standard on July 21, 2014.\11\ Section 4.3 of the 2014 ANSI/WCMA standard specifies that window coverings with an exposed operating cord or continuous loop operating system shall meet one of the following requirements:

      ---------------------------------------------------------------------------

      \11\ Changes to the descriptive text found in the ANSI/WCMA Standard, Appendix E, Figure E1, Row 3.

      4.3.1: Product shall have no accessible operating cords

      4.3.2: Product shall have one or more separate operating cords

      4.3.3: Product shall contain a cord release device in the loop or head rail

      4.3.4: Product shall contain a permanently attached cord retraction device

      4.3.5: Product shall contain a cord shear device

      4.3.6: Product shall contain a cord shroud device

      4.3.7: Product shall contain a cord tension device

      4.3.8: Product shall contain a loop cord or bead chain-restraining device

      4.3.9: If the product requires a cord connector, i.e. stop ball, the exposed loop above the cord connector shall be limited to less than 3 inches below the bottom of the cord lock when the bottom rail is fully lowered.

      Thus, the ANSI/WCMA standard allows for separate operating cords, cord release devices, cord retractors, cord shrouds, cord tensioners, and loop/bead chain restraining devices.

      2. Warning Labels

      In addition to performance requirements, the ANSI/WCMA standard requires a number of warning labels and hangtags on window coverings, all of which are accompanied with a pictogram. ANPR Briefing Memorandum at 5.

    2. Substantial Compliance With the Voluntary Standard

      According to the WCMA, manufacturers of window coverings are in substantial compliance with the voluntary standard. Beyond WCMA's comments, CPSC has no data on the extent of compliance and cannot estimate the proportion of annual sales of window covering products that comply. CPSC has some anecdotal information on product compliance and incident hazard patterns that lends support to WCMA's contention that products substantially comply with the voluntary standard. For example, the 1996 version of the standard required that pull cords have separate tassels or a breakaway tassel to reduce the hazard with the loop above a single tassel. Among the incidents associated with the loop above a single tassel, staff's review of incidents showed that only one product out of 14 products involved in incidents was manufactured after the 1996 standard went into effect and did not comply with the requirement. Petition Briefing Package, Briefing Memorandum at 18.

    3. Engineering Staff's Assessment of ANSI/WCMA Standard

      1. Performance Requirements

      For the Petition Briefing Package, the Division of Mechanical Engineering (ESME) reviewed the incident data to determine whether the 2014 version of the ANSI/WCMA standard would address the hazards presented in the 249 IDIs reviewed by staff. Petition Briefing Package, Tab E. According to ESME staff's assessment, the 2014 version of the ANSI/WCMA standard addresses the hazards in 25.7 percent (64/249) of the investigated incidents, while hazards reported in 57 percent (141/

      249) are not addressed by the ANSI/WCMA standard. Insufficient information was available to draw any conclusions for the remaining 17.7 percent (44/249) of investigated incidents. Id. at 123-124.

      Table 3 summarizes the hazard types identified in the 249 IDIs reviewed by CPSC staff, and ESME's assessment of the hazard addressability with the current 2014 version of the voluntary standard. An Appendix to Tab E of the Petition Briefing Package includes more detailed descriptions of each of these hazard scenarios.

      Page 2338

      Table 3--Addressability of the Hazards With the 2014 ANSI/WCMA Standard

      ----------------------------------------------------------------------------------------------------------------

      Entanglement mechanism (hazard Number of Investigated Section of the standard

      scenario in Table 2) incidents IDIs (%) related to the hazard Conclusion

      ----------------------------------------------------------------------------------------------------------------

      1. Entanglement from pull cords 69 27.7 ....................... Not addressed.

      14 5.6 ....................... Addressed.

      Entanglement in a loop created 38 15.3 Section 4.3.2 allows Not addressed.

      by knotted or tangled pull multiple cords in

      cord (hazard scenario 1). unspecified lengths.

      Entanglement in one or more 25 10.0 Sections 4.3.2 and Not addressed.

      long cords, which the child 4.3.9 allow accessible

      wrapped around the neck free hanging operating

      (hazard scenario 2). cords.

      Entanglement in a loop above a 14 5.6 Sections 4.3.2 and Addressed.

      single tassel of the cord 4.3.3 require either

      (hazard scenario 3). separate cords or

      cords with release

      devices in the loop.

      Entanglement in a loop above 4 1.6 Section 4.3.9 allows Not addressed.

      the stop ball of the cord for an accessible loop

      (hazard scenario 4). when the bottom rail

      is fully raised.

      Entanglement in a loop created 2 0.8 Section 4.3.2 allows Not addressed.

      when pull-cord was tied to unspecified length of

      another object, usually on the cords.

      wall (hazard scenario 5).

      2. Entanglement in a continuous 70 28.1 Section 4.3.7 requires Not addressed.

      loop cord (hazard scenario 6). a cord tension device

      that will at least

      partially prevent the

      operation of the

      window covering, when

      not installed but

      still allows some

      operability.

      3. Entanglement from inner 47 18.9 Section 4.4 addresses Addressed.

      cords (hazard scenarios 7 and accessibility and

      8). hazardousness of inner

      cord loops.

      4. Entanglement in the lifting 3 1.2 Section 4.4.5 addresses Addressed.

      loop of a roll-up shade the accessible lifting

      (hazard scenario 9). loops of a roll-up

      style shade.

      5. Entanglement in the tilt 2 0.8 Section 4.3.2 allows Not addressed.

      cords (hazard scenario 2). multiple cords in

      unspecified lengths.

      6. Unknown..................... 44 17.7 ....................... Unknown.

      ----------------------------------------------------------------------------------------------------------------

      Although the standard does address a portion of the hazards associated with pull cords, remaining pull cord hazards and continuous loop cords account for more than 50 percent of the hazard scenarios that are not addressed by the standard.

      Continuous Loops. Continuous loops need to be kept taut so that the free-standing loop does not cause a hazard to young children. The voluntary standard requires a tension device to be attached on the loop by the manufacturer. After receiving the product, the consumer must install the tension device on an external surface, such as a wall or window sill, per manufacturer's instructions. As explained in the ESHF memorandum, Tab D of the Petition Briefing Package, compliance with instructions declines if the effort and time required for the installation is high. The first publication of the voluntary standard (1996) required that a cord tension device be supplied and removal of it is a sequential process (i.e., requires two or more independent steps to be performed in a specific order). Once the tension device is installed, it becomes a passive device.

      In 2007, the voluntary standard introduced the ``partial inoperability clause,'' which meant that if the tension device was not properly installed, the tension device should at least partially prevent the operation of the window covering. The latest version of the standard includes the same partial inoperability requirement, in addition to a new durability test procedure to prevent the tension device, if installed, from coming off the wall or breaking under the tested conditions.

      Pull Cords. For the Petition Briefing Package, ESME staff concluded that the voluntary standard does not address the following hazard scenarios: (1) Loops resulting from knotted or entangled pull cords, (2) pull cords that are wrapped around the neck, (3) pull cords that are tied to another object, and (4) pull cords with loops above stop ball/cord connector. The recently published Canadian standard (CAN/CSA-

      Z600-14 Safety of Corded Window Covering Products) adopts the requirements of the ANSI/WCMA standard with one change: adding cord cleats as a required component to mitigate the pull cord hazard. CPSC understands that for the spirit of harmonization, WCMA will propose to include a similar requirement to the ANSI/WCMA standard.

      CPSC staff has raised concerns regarding the pull cord and continuous loop hazards to WCMA, repeatedly emphasizing that either eliminating access to the pull cords or making accessible cords nonhazardous in both raised or lowered heights of the window covering would greatly reduce the incidents. Most recently, on July 22, 2014, CPSC staff sent a letter to WCMA suggesting revisions to the voluntary standard that would address the strangulation hazard created by pull cords and continuous loops on window coverings.\12\ WCMA responded to staff's letter on August 29, 2014.\13\ ANPR Briefing Memorandum at 4.

      ---------------------------------------------------------------------------

      \12\ http://www.cpsc.gov//PageFiles/170256/WCMA_Ltr_22_July_2014.pdf.

      \13\ http://www.cpsc.gov//PageFiles/170642/WCMALettertoGBorlase8_29.pdf.

      ---------------------------------------------------------------------------

      WCMA believes that cord cleats, a device around which a cord can be wound and can be attached to a wall or other structure, or that is integral with the product, can help reduce incidents associated with pull cords. WCMA intends to utilize an expedited approval process to add cord cleats as a requirement to the ANSI/WCMA standard with the objective of harmonizing the standard with the latest version of the Canadian standard (CAN/CSA Z600 window covering standard).

      Staff has several concerns with cord cleats. Cord cleats require that the user remove and then secure the cord to the cleat each time the window covering is raised or lowered in order to mitigate the hazard, which consumers may feel to be a nuisance and not do, thus voiding the protections ostensibly provided. In addition, failure to install a cord cleat will not cause the window covering to cease operating as intended, which may also serve to reduce the

      Page 2339

      protection provided. Indeed, many stock products already come with cord cleats in the box, so the degree to which they are installed and used is in question. For example, in a 2010 incident, a four-year-old child who was standing on the back of a couch, reached the pull cords which were usually wrapped around the cord cleat, but not on the day of the incident.\14\ When cord cleats are installed, consumers still need to be aware that children can climb up to get to the cords, as observed in a 2005 incident where a four-year-old child moved a small plastic table near to a window, climbed upon the table, reached up and removed the pull cord.\15\ Furthermore, even if cleats are used to wrap excess pull cords, the cords above the cleat present a strangulation hazard.\16\ A cord cleat retrofit program may be beneficial for those consumers who become aware of the hazard and want to take action to mitigate the pull cord hazard. However, staff believes that consumers who respond to a recall likely install and use cord cleats more consistently than consumers who are unaware of the hazard. The latter group of consumers may overlook the cord cleat as they are not aware of the hazard, and the operation of the product does not necessitate the installation and use of cord cleats.

      ---------------------------------------------------------------------------

      \14\ IDI 110103CCC3322.

      \15\ IDI 050407CCC3309.

      \16\ http://www.cpsc.gov/PageFiles/121510/5009a.pdf.

      ---------------------------------------------------------------------------

      Regarding continuous loops and tension devices, CPSC staff's IDI review of 70 incidents associated with entanglement in a continuous loop cord showed that the majority of the incident units did not have a tension device installed on the continuous loop. Staff recognizes that tension devices, when properly installed and intact, keep the looped cords taut and do not allow a child's head to enter into the loop. If tension devices are not installed, are installed improperly, or are removed from the cord, a hazardous loop is present. ANPR Briefing Memorandum at 4.

      2. Warning Labels

      Warning labels are intended to alert the user of the strangulation hazard, and to keep cords away from children and move furniture away from cords as children can climb on furniture to reach cords. Warning labels and hang tags have been part of the ANSI/WCMA standard since its first publication in 1996. In 2009, the voluntary standard required a hang tag that must be attached to the lower most section of the inner cord on the back side of a Roman shade. The voluntary standard was amended in 2012 to require that a warning label be placed on the product package (or on merchandising material for custom products) and displayed conspicuously. The requirement to include warnings on retail packaging and merchandising materials was intended to warn consumers about the strangulation hazard associated with accessible cords so that consumers can make an informed purchasing decision.

      Staff believes that the requirement to place a warning on product packaging is potentially beneficial for consumers who either learn of the hazard by reviewing the warning material on packaging or are aware of the hazard and looking for a safer product to purchase. However, consumers who are not the original purchasers of the product will not benefit from information included on packaging materials as the packaging is discarded after the product is installed.

      The ANSI/WCMA standard requires permanent warning labels \17\and operational hangtags \18\ on the product that follow ANSI Z535.4, American National Standard for Product Safety Signs and Labels. Research demonstrates that warning labels should first be visible and noticeable. Warning labels should also have design characteristics that encourage the user to stop and read the warning. Effective labels state the hazard, explain the consequences of the hazard, and provide instructions on how to avoid the hazard using explicit text to improve comprehension. Staff believes that warning labels on window coverings that comply with the ANSI/WCMA standard have design characteristics to make them visible and noticeable. For example, warnings that are placed directly on the product have higher noticeability compared to the warnings listed in a ``distant'' instruction manual (Wogalter et al., 1987). Additionally, the voluntary standard requires the word ``Warning'' in all capital letters and printed in an orange color. The required warning messages that are on the warning labels and hang tags explain the nature of the hazard, the consequences of the hazard, and provide instructions on how to avoid the hazard, as recommended in the warning literature (Wogalter and Laughery, 2006). Finally, the required labels have a pictogram which should increase their noticeability because pictograms help capture user's attention (Wogalter and Leonard 1999).

      ---------------------------------------------------------------------------

      \17\ A permanent marking or label cannot be removed or, during an attempt to manually remove it without the aid of tools or solvents, the marking or label tears apart or damages the surface to which it is attached.

      \18\ Operational hangtags contain information based on the characteristics of the product or the safety devices included on the product.

      ---------------------------------------------------------------------------

      Even though the warning labels required by the ANSI/WCMA standard meet the usual criteria for what is considered a well-designed warning label, CPSC staff believes that the labels have limited effectiveness in changing the user's behavior in the purchase and use of window coverings. The inherent problem with the strangulation hazard associated with window covering cords and warning labels is that people are less likely to read instructions or recognize potential hazards associated with the products that they use more frequently (Godfrey et al., 1994). Research demonstrates that high familiarity with a product can lower a user's inclination to read warnings or reduce the likelihood that the user will believe such information, lowering the rate of compliance with the warning (Riley, 2004). Window coverings are decorative products providing utility and found in every household in one form or another. Consumers interact with window coverings daily and experienced users are likely to repeat behaviors with little conscious thought, especially on a product that they have had numerous prior experiences (Riley, 2004).

      Even after users notice and read the warning label, comprehend the message and make the decision to follow the instructions, they must comply with the warning as instructed to mitigate the hazard. User's actual ability to comply with a warning is affected by cost of compliance, which includes effort, time, and perceived compromise in product performance as well as expense. In the case of window coverings, safety recommendations other than purchasing inherently safe products (e.g., cordless products or products with inaccessible cords), such as keeping cords out of reach of children, moving the furniture away from cords, installing a tension device to the wall or floor, and installing cord cleats, entail significant limitations or high cost of compliance. For example, depending on the room design limitations, consumers may not have the ability to keep cords away from furniture. Additionally, requiring consumers to wrap the pull cords around the cord cleat each and every time the window covering is raised or lowered leads to potential errors, such as forgetting the intended action during the routine use of the product. ANPR Briefing Memorandum at 5-6.

      Page 2340

    4. Available Technology To Address the Hazard

      Although not currently mandatory, a variety of technologies currently used by window covering manufacturers on window covering products eliminate the risk of strangulation to young children. CPSC's engineering staff reviewed window covering products currently on the market that incorporate technologies to address the hazard associated with corded products. Petition Briefing Package, Tab E at 130-136. Available products that address the hazard include, but are not limited to: Manual and motorized cordless window coverings, cord shrouds, and cord retractors.

      Cords can be made inaccessible with passive guarding devices. Passive guarding devices allow the user to operate the window covering without direct interaction of a hazardous cord. These types of devices would include cord shrouds, integrated cord/chain tensioners, or cord retractors.

      Cordless blinds and shades are raised and lowered by pushing the bottom rail up or pulling the rail down. This same motion may also be used to adjust the position of the horizontal slats for light control. Through market research, staff found several examples of cordless blinds that can be made with a maximum height 84'' and a maximum width of 144''.

      Rigid cord shrouds (Figure 9) can be retrofitted over various types of window coverings to enclose pull cords and continuous cord loops. An encased clutch system allows the user to utilize the pull cords in the cord shroud while eliminating access to the hazardous cords.

      GRAPHIC TIFF OMITTED TP16JA15.011

      Loop cord/bead chain restraining devices (Figure 10) keep the looped bead chain taut, preventing access to a hazardous loop, and do not require external components to be installed.

      GRAPHIC TIFF OMITTED TP16JA15.012

      Crank mechanisms (Figure 11) replace the continuous loop mechanism with a crank/wand mechanism. Because the operating cord is replaced with a wand, the strangulation hazards are completely removed.

      Page 2341

      GRAPHIC TIFF OMITTED TP16JA15.013

      Cord retractors (Figure 12) passively retract the operating cord within 6 inches of the head rail. These devices are intended to keep the operating cords out of the child's reach. Through market research, staff found several examples of cord retractors that can be used on window coverings with a maximum height of 120'' and a maximum width of 174''.

      GRAPHIC TIFF OMITTED TP16JA15.014

      Cordless motorized blinds are raised and lowered using an electric motor with a supplied controller. These products function in a manner similar to the motorized projector screens. Because these products use a motor instead of a pull cord, there are no exposed hazardous cords.

      Table 4 groups the hazard patterns with the appropriate available technologies.

      Table 4--Hazard Patterns With Available Technologies

      ----------------------------------------------------------------------------------------------------------------

      Does the ANSI/WCMA Available

      Standard technology

      ANSI/WCMA effectively (commercially

      Hazard Products requirements address the hazard available or in

      per engineering prototype stage)

      staff's assessment to address hazard

      ----------------------------------------------------------------------------------------------------------------

      Hazard 1. Loops created by Horizontal blinds, 4.3.2 The product No--free hanging, Cordless window

      knotted or tangled cord. Cellular shades, shall have one or exposed operating coverings, rigid

      Roll up blinds, more separate cords are cord shrouds,

      Roman shades, operating cords. permissible. crank mechanisms,

      Pleated shades. cord retractors,

      cordless

      motorized window

      coverings.

      Page 2342

      Hazard 2. One or more long cords Horizontal blinds, 4.3.2 The product No--accessible, Cordless window

      which the child wrapped around Cellular shades, shall have one or free hanging coverings, rigid

      the neck involving pull cords Roll up blinds, more separate cords can be cord shrouds,

      and tilt cords. Roman shades, operating cords. wrapped around crank mechanisms,

      Pleated shades. 4.3.9 The product the neck of a cord retractors,

      shall, if it child as incident and, cordless

      requires a cord data demonstrates. motorized window

      connector, limit coverings.

      the exposed loop

      above the cord

      connector to less

      than 3 inches

      below the bottom

      of the cord lock

      when bottom rail

      is in the fully

      lowered position..

      Hazard 3. Loop above a single Horizontal blinds, 4.3.2 The product Yes--by requiring ..................

      tassel of the cord. Cellular shades, shall have one or either separate

      Roll Up blinds, more separate tassels on each

      Roman shades, operating cords. cord or breakaway

      Pleated shades. 4.3.3 The Product tassel, however

      shall contain a this separate

      cord release tassel

      device in the configuration

      loop or the head presents a

      rail.. wraparound

      (hazard #1) or

      knotted loop

      (hazard#2)

      strangulation

      hazards as

      described above.

      Hazard 4. Loop above the stop Horizontal blinds, 4.3.9 The cord No--a product that Cordless window

      ball of the cord. Cellular shades, connector shall meets the coverings, rigid

      Roll up blinds, limit the exposed standard could cord shrouds,

      Roman shades, loop above the still contain an crank mechanisms,

      Pleated shades. cord connector to accessible cord retractors,

      less than 3 hazardous loop and, cordless

      inches below the when the bottom motorized window

      bottom of the rail is raised. coverings.

      cord lock when

      the bottom rail

      is fully lowered.

      Hazard 5. Loop created when pull- Horizontal blinds, 4.3.2 The product No--consumers may Cordless window

      cord was tied to another Cellular shades, shall have one or attempt to keep coverings, rigid

      object, usually on the wall. Roll up blinds, more separate the long cords cord shrouds,

      Roman shades, operating cords. away from crank mechanisms,

      Pleated shades. children by tying cord retractors,

      the cords on a and, cordless

      curtain rod or motorized window

      other means. coverings.

      Hazard Unknown manner (involving Horizontal blinds, N/A............... Unknown........... Unknown.

      a pull cord). Cellular Shades,

      Roll Up blinds,

      Roman Shades,

      Pleated shades.

      Hazard 6. Entanglement in a Vertical blinds, 4.3.7 The product No--hazardous Loop cord/bead

      continuous loop cord. Roller shades, shall contain a loops are not restraining

      Curtains and cord tension effectively device, crank

      draperies. device that will addressed by the mechanisms,

      at least standard when the motorized option.

      partially prevent blind continues

      the window to be

      covering from operational,

      functioning for despite the fact

      light control or that the tension

      privacy when not device is not

      installed. properly

      installed.

      Hazard 7a. Entanglement from Horizontal blinds. 4.4.1 the product Yes--window

      exposed inner cords with no shall have no coverings

      cord stops. inner cords. associated with

      4.4.2 no the inner cord

      accessible inner hazard scenario

      cords. appeared to be

      4.4.3 accessible older products

      inner cords shall that were

      pass the manufactured

      hazardous loop before the 2002

      test. standard was

      4.4.3.1 inner cord published.

      stop devices or Engineering staff

      cord connectors believes that had

      shall be the cord stops

      positioned 3 involved in the

      inches or less incident

      below the head scenarios met the

      rail. voluntary

      4.4.4 shrouded standard, they

      inner cords. would not likely

      have occurred.

      Page 2343

      Hazard 7b. Entanglement from Horizontal blinds. 4.4.1 the product Yes--window

      exposed inner cords when the shall have no coverings

      cord stops are positioned too inner cords. associated with

      low. 4.4.2 no the inner cord

      accessible inner hazard scenario

      cords. appeared to be

      4.4.3 accessible older products

      inner cords shall that were

      pass the manufactured

      hazardous loop before the 2002

      test. standard was

      4.4.3.1 inner cord published.

      stop devices or Engineering staff

      cord connectors believes that had

      shall be the cord stops

      positioned 3 involved in the

      inches or less incident

      below the head scenarios met the

      rail. voluntary

      4.4.4 shrouded standard, they

      inner cords. would not likely

      have occurred.

      Hazard 8. Entanglement in the Roman shades...... 4.4.1 the product Yes--the

      Roman shade inner cord. shall have no requirements

      inner cords. prevent hazardous

      4.4.2 no inner cords that

      accessible inner may allow child's

      cords. head to be

      4.4.3 accessible inserted to the

      inner cords shall loop.

      pass the

      hazardous loop

      test.

      4.4.3.1 inner cord

      stop devices or

      cord connectors

      shall be

      positioned 3

      inches or less

      below the head

      rail.

      4.4.4 shrouded

      inner cords.

      Hazard 9. Entanglement in the Roll up blind..... 4.4.5 accessible Yes--the lifting

      lifting loop. inner cords shall loop shall be

      feature an inner pulled 48 times

      cord release in various

      device. directions. The

      lifting loop

      shall breakaway

      with an average

      force not to

      exceed 3 pounds.

      This test mimics

      the force that

      may be exerted

      due to the

      child's head

      being in the loop.

      ----------------------------------------------------------------------------------------------------------------

    5. Compliance Actions

      Compliance staff began working with WCMA in 1994, when CPSC announced a joint recall with the WCMA on how to eliminate the loops on pull cords ending in one tassel. Petition Briefing Package, Tab F. The WCMA created the larger Window Covering Safety Council (WCSC) to include window covering manufacturers and retailers to support the recall and to provide free repair kits to consumers. In 1999, after an extensive review of the incidents reported to CPSC, Compliance staff began a new investigation of window covering deaths resulting from inner cords of horizontal blinds. In 2000, CPSC and WCMA again announced a joint recall involving inner cord stops to reduce the risk of a child pulling on the inner cords and creating a hazardous loop. Id. at 142-143.

      In 2005, Compliance staff learned of a nonfatal incident involving the inner cord of a Roman shade. Subsequently, CPSC investigated a worldwide retailer following a child's death from the inner cord of a Roman shade. In 2008, CPSC and the retailer announced a joint recall for Roman shades, offering a full refund to consumers. In 2009, CPSC and 15 manufacturers and retailers in conjunction with the WCSC, announced individual recalls of Roman shades and roll-up blinds. In 2012, two more recalls occurred: One involving horizontal blinds manufactured without inner cord stops and vertical blinds manufactured without tension devices, and the second recall to repair and correct an assembly error in a breakaway cord connector. Id. at 143-145.

    6. Public Education

      Since the window covering-related first safety alert was issued in 1985, CPSC has been warning parents of the danger of child strangulation due to corded window coverings. Petition Briefing Package, Briefing Memorandum at 19. CPSC identified window coverings as one of the top five hidden home hazards.\19\ Every October, CPSC participates jointly with WCSC in National Window Covering Safety Month to urge parents and caregivers to check their window coverings for exposed and dangling cords and to take precautions. Both CPSC and WCSC recommend cordless window coverings or window coverings with inaccessible cords in homes where young children live or visit. In addition to traditional communication methods, CPSC reaches out to consumers using social media, such as safety blogs and online chats, the Neighborhood Safety Network, and

      Page 2344

      through partnerships (such as with the Department of Defense) to create awareness of the hazards associated with corded window coverings. CPSC does not have information to assess the effectiveness of public education campaigns.

      ---------------------------------------------------------------------------

      \19\ http://www.cpsc.gov/PageFiles/165163/hidden.pdf.

      ---------------------------------------------------------------------------

  5. Existing Standards for Window Covering Products

    1. ANSI/WCMA Standard

      Although no mandatory window covering standard exists in the United States, the 2014 version of the ANSI/WCMA voluntary standard establishes safety performance requirements.. The standard applies to all interior corded window covering products sold in the United States and includes, but is not limited to, cellular shades, horizontal blinds, pleated shades, roll-up style blinds, roller shades, Roman style shades, traverse rods, and vertical blinds. The standard was first published in 1996, and subsequently was revised six times. The latest version was published in 2014. Section IV.A-C of this ANPR review provisions in the ANSI/WCMA standard intended to address the hazard creating by corded window coverings.

    2. International Standards

      Three international standards specify requirements for the safety of window coverings:

      (1) Competition and Consumer (Corded Internal Window Coverings) Safety Standard 2014 published in Australia (Australian standard),

      (2) Corded Window Covering Products Regulations (SOR/2009-11) and CAN/CSA-Z600-14 Safety of Corded Window Covering Products published in Canada, which is based on the 2012 ANSI/WCMA standard with some modifications (Canadian standard), and

      (3) EN 13120:2009+A1:2014 Internal blinds--Performance requirements including safety, EN 16433:2014 Internal blinds--Protection from strangulation hazards--Test methods, and EN 16434:2014 Internal blinds--Protection from strangulation hazards. Requirements and test methods for safety devices published by European Committee for Standardization (European standard).

      CPSC engineering staff compared the ANSI/WCMA standard with the international standards and concluded that the ANSI standard developed by WCMA is one of strongest standards in the world. Petition Briefing Package, Tab E at 124-130.

      1. Australian Standard

      Australia has a mandatory product safety standard requiring the provision of information, warnings, instructions, and safety devices with corded internal window coverings (CIWC). A new regulation has been enacted requiring those installing CIWC in trade or commerce to follow the safety instructions when installing the product and avoid the production of dangerous lengths or loops of cord.

      A corded internal window covering must be installed to meet the following four requirements:

      a. A loose cord cannot form a 220 mm loop or longer at less than 1600 mm (62.99 in.).

      b. The product must be installed using the installation instruction on the retail packaging and any other provided information about how to ensure a loose cord cannot form a loop described in requirement 1.

      c. No part of the cord guide (a device designed to retract, tension, or secure a cord) may be installed lower than 1600 mm above floor level unless:

      i. The cord guide will stay attached to the wall when subjected to 70 N applied in any direction for 10 seconds.

      ii. The cord is sufficiently secured or tensioned to prevent the formation of a loop 220 mm or longer.

      d. If a cleat is used to secure a cord, it must be installed at least 1600 mm above the floor level.

      CPSC does not believe the use of a cord cleat is effective to address the strangulation risk.\20\ First, a cord cleat needs to be actively installed and used every time. Second, the cord cleat needs to be installed at a height not accessible to a child. If the child had access to the cord cleat, the resulting hazard would be similar to hazard 5: Loop created when pull-cord was tied to another object, usually on the wall. Finally the cord cleat needs to take up all the excess slack in the cord; excess cord slack could pose a hazard similar to the hazard created by loops created by knotted or tangled cord or one or more long cords which the child wrapped around the neck (see Table 3).

      ---------------------------------------------------------------------------

      \20\ Ibid.

      ---------------------------------------------------------------------------

      2. Canadian Standard

      Canada's most recent standard, CAN/CSA-Z600-14, is the 2012 ANSI/

      WCMA standard with the inclusion of cord cleats. Cord cleats are required for window coverings with accessible cords and shall allow complete cording length to be accumulated on the cleat. Instructions on how to properly use the cord cleats are also required. Consumers will be advised that the cord cleats that are external to the product should be installed at a height of 1.6 m above the floor, while cord cleats integral to the product shall be within 18 inches of the head rail. CPSC maintains the same opinion about cord cleats as explained above in section V.B.2 regarding the Australian standard.

      3. European Standard

      Many differences exist between the WCMA and European standards, with each standard having areas of strength and weakness. Table 5 compares the operating cord requirements of the ANSI/WCMA standard and the European standard.

      Page 2345

      Table 5--Comparison of ANSI/WCMA Standard With the European Standard

      ----------------------------------------------------------------------------------------------------------------

      Test ANSI/WCMA A100.1-2014 EN Standard Summary

      ----------------------------------------------------------------------------------------------------------------

      Cord Release Device/Cord Shear Device Cord Release Device & Breakaway system: The ANSI/WCMA standard

      vs. Breakaway System. Cord Shear Device: *If installation height appears to be more

      *Create a 3.5 foot loop is not given, the conservative because

      from the cord and hook length of pull cord(s) it requires the cord

      a force gage onto it. shall be less than or to break away at an

      *Twist the force gauge equal to \2/3\ of the average of 3 pounds,

      360 degrees and draw height of the curtain.. compared to EN's 13.22

      the force gauge at a *If the installation pounds.

      speed between .1 and 1 height is given, the

      inch per second. The pull cords shall be at

      cord shall release least .6 m above the

      within 10 seconds.. floor..

      *Repeat for 50 products *The hazardous loop

      *The average release shall be eliminated

      force shall not exceed when a mass of 13.22

      3 pounds for the 50 pounds is gradually

      products and all applied to the pull

      products shall have a cords within 5 seconds

      release force below 5 of application..

      pounds..

      Cord tension vs. Fixed Tensioning *The tension device *If the blind's height The ANSI/WCMA standard

      system. shall at least is 2.5 m, then the installed by partially

      control or privacy pull cords shall be 2.5 m, the pull cord pounds while the WCMA

      meet one of the length shall be no allow for forces up to

      following longer than the 13.3 pounds.

      requirements: curtain height minus The EN standard is

      4.3.1: Product shall 1.5 m.. stronger in terms of

      have no accessible If the product has two the following:

      operating cords. pull cords:. *It ensures that

      4.3.2: Product shall *Pull cords shall not tangled cords become

      have one or more tangle.. eliminated within 5

      separate operating *If cords tangle, the seconds of a 13.22-

      cords. loop shall be pound application,

      4.3.3: Product shall eliminated within 5 WCMA has no such

      contain a cord release seconds of a 6 kg mass requirement.

      device in the loop or application.. *It restricts the

      head rail. *Pull cords shall be length on continuous

      4.3.4: Product shall connected using a loop and breakaway

      contain a permanently breakaway system. The pull cords to reduce

      attached cord hazardous loop shall access to the cord. If

      retraction device. be eliminated within 5 the product does not

      4.3.5: Product shall seconds of a 6kg mass meet the length

      contain a cord shear application.. requirements, then the

      device. If the product has more product must be fitted

      4.3.6: Product shall than two pull cords:. with an accumulation

      contain a cord shroud *Pull cords shall be system to contain all

      device. connected together of the excess cord,

      4.3.7: Product shall using a breakaway not allowing more than

      contain a cord tension system.. 100 mm of cord when

      device. *The hazardous loop 60N is applied to it.

      4.3.8: Product shall shall be eliminated The WCMA standard does

      contain a loop cord or within 5 seconds of a not restrict the pull

      bead chain-restraining 6kg mass application.. cord length and the

      device. If the product has more cord retractor is an

      4.3.9: If the product than four pull cords optional requirement.

      requires a cord in the absence of a *In addition to the

      connector, i.e. stop suitable breakaway length requirement, it

      ball, the exposed loop connector:. requires the pull

      above the cord *Cords may be connected cords to either be

      connector shall be to a single pull cord connected with a

      limited to less than 3 positioned The product has no accessible cords under any conditions of foreseeable use or misuse.

      The product has accessible cords that cannot form a hazardous loop under any conditions of foreseeable use or misuse, including failure to heed warnings or incorrect installation.

      The following approach provides for the next level in the hierarchy of solutions to reduce strangulation hazard:

      The product is provided with safety devices to be installed ensuring that accessible cords cannot form a hazardous loop. Instructions and warnings are provided for correct installation.

      Due to variable factors, such as a consumer's diligence and ability to follow all installation instructions and heed all warnings, there is a difference between this approach and the approach providing the highest level of safety. Finally, relying solely on warnings that the product contains hazardous loops that could strangle a child is considered insufficient to prevent fatalities.

      Warnings and instructions for safe use however should continue to be present on all corded window coverings, their packaging, and their instructions. Public education efforts should encourage the use of safe window coverings and removal of products with accessible cords that can form hazardous loops.

  6. Relevant Statutory Provisions

    The Commission is conducting this proceeding under the Consumer Product Safety Act (``CPSA''). 15 U.S.C. 2051 et seq. Window covering products are consumer products. Id. 2052(a)(5). Under section 7 of the CPSA, the Commission can issue a consumer product safety standard if the requirements of such a standard are ``reasonably necessary to prevent or reduce an unreasonable risk of injury associated with a consumer product.'' Id. 2056(a). Such a standard must be expressed in terms of performance requirements or requirements for warnings or instructions. Id. Under section 8 of the CPSA, the Commission can issue a rule declaring a product to be a banned hazardous product when the Commission finds that a consumer product is being, or will be, distributed in commerce and there is no feasible consumer product safety standard that would adequately protect the public from the unreasonable risk associated with the product. Id. 2057.

    Section 9 of the CPSA sets out the procedure that the Commission must follow to issue a standard or a banning rule. The rulemaking may begin with an ANPR that identifies the product and the nature of the risk of injury associated with the product, summarizes the regulatory alternatives considered by the Commission, and provides information about any relevant existing standards and a summary of the reasons the Commission believes they would not eliminate or adequately reduce the risk of injury. The ANPR also must invite comments concerning the risk of injury and regulatory alternatives and invite the public to submit an existing standard or a statement of intent to modify or develop a voluntary standard to address the risk of injury. Id. 2058(a).

    The next step in the rulemaking would be for us to review comments submitted in response to the ANPR and decide whether to issue a proposed rule along with a preliminary regulatory analysis. The preliminary regulatory analysis would describe potential benefits and costs of the proposal, discuss reasonable alternatives, and summarize the potential benefits and costs of the alternatives. Id. 2058(c). We would then review comments on the proposed rule and decide whether to issue a final rule along with a final regulatory analysis. Id. 2058(d) through (g).

  7. Preliminary Estimate of Societal Costs

    Tab G of the Petition Briefing Package estimates societal costs associated with deaths and injuries from corded window covering products. Based on deaths reported from 1999 through 2010, and medically attended injuries from 1996 through 2012, the societal costs associated with deaths and injuries involving window covering cords may have amounted to an average of about $110.7 million annually. EC staff estimated that an average of about 20 percent of the window coverings\21\ were cordless (or did not have accessible cords) during the 1996 through 2012 time period, which suggests that these injuries and deaths were associated with the roughly 832 million window coverings in use that had accessible cords.

    ---------------------------------------------------------------------------

    \21\ Based on EC staff's estimate that about 25 percent of current market sales consist of cordless products, the increasing availability and sales of cordless products in recent years, and the assumption that only about one-third of curtains and draperies have cords.

    ---------------------------------------------------------------------------

    Based on the estimates provided in the Petition Briefing Package, the societal costs may have amounted to an average of about $0.13 per corded window covering per year (i.e., $110.7 million / 832 million window coverings) from 1996 through 2012. Additionally, because window coverings remain in use for an average of about 7 years, the expected present

    Page 2348

    value of the annual societal costs (discounted at a rate of 3.0 percent) would average about $0.85 per corded covering over its expected product life.

  8. Regulatory Alternatives

    The Commission is considering the following alternatives to address the risk of injury associated with corded window covering products:

    1. Mandatory Standard

      The Commission could issue a rule specifying performance requirements for corded window coverings to reduce the risk of injury identified with these products. For example, to address the pull cord and continuous loop hazards, one option may be to develop a mandatory rule that is similar to the current ANSI/WCMA standard, which provides manufacturers a list of options to make safe window coverings. Such a rule could require that pull cords and continuous loops be tested for accessibility similar to the inner cords that are currently required by the standard. If accessible cords are found, a hazardous loop test procedure similar to the current procedure, but with some modifications, could be applied to determine if cords can create a hazardous loop.

      Another option for a mandatory rule would be to issue a rule consistent with the petitioners' request, which would prohibit window covering cords if a feasible cordless alternative exists; and for instances in which a feasible cordless alternative does not exist, require that all cords be made inaccessible by using a passive guarding device.

      A third option for a mandatory rule may be to model such a rule after one of the enumerated international standards in section VII, or relevant portions of such standards.

      For any mandatory rule, the Commission could issue a rule that focuses on performance requirements or issue a rule that includes both performance requirements and labeling requirements to address the risk of strangulation. The Commission is interested in comments on the approaches described above, as well as any other suggestions to develop a mandatory standard to address the risk of injury associated with window covering cords. To issue a mandatory standard, the Commission would need to assess the costs and benefits of the requirements. Accordingly, the CPSC is interested in an assessment of the costs and benefits associated with options for a mandatory rule.

    2. Labeling Rule

      The Commission could issue a mandatory rule that relies on warning labels. CPSC staff is concerned that warning labels have limited effectiveness for a product that is familiar, used frequently, and contains a hidden hazard, as explained in Section IV.C.2 of this notice.

    3. Banning Rule

      The Commission could issue a rule declaring window covering products with cords to be banned hazardous products, if we found that no feasible consumer product safety standard would adequately protect the public from the unreasonable risk of injury associated with these products.

    4. Reliance on Voluntary Standard

      If the Commission determines that a voluntary standard is adequate to address the risk of injury associated with corded window covering products, and that substantial compliance with the standard exists in the industry, we must rely on the voluntary standard, in lieu of issuing a mandatory rule. 15 U.S.C. 2058(b)(2).

      If the Commission announces in the Federal Register its intention to rely on the voluntary standard, this would obligate manufacturers, distributors, and retailers to report any product that does not comply with the standard, even a product with no incidents. 15 U.S.C. 2064(b)(1). Failure to report could result in penalties. 15 U.S.C. 2068(a)(4).

      As explained in the Petition Briefing Package, CPSC engineering staff believes the current version of the ANSI/WCMA voluntary standard would fail to eliminate or adequately reduce the strangulation hazard to children because at least 57 percent of the incidents that occurred could still occur with pull cords and continuous loops on window coverings that meet the current version of the ANSI/WCMA standard.

    5. No Regulatory Action

      The Commission could take no regulatory action but continue to rely on corrective actions under section 15 of the CPSA and/or public education campaigns to address the risk of injury associated with corded window covering products. The Commission could continue to rely on recalls to address hazards associated with window coverings. For example, CPSC and WCMA announced joint recalls to eliminate the loops on pull cords ending in one tassel by offering free tassels; to reduce the incidents associated with horizontal blind inner cords by offering free inner cord stops, and repair kits to remove inner cords from Roman shades. The ANSI/WCMA standard was revised accordingly after these recalls to add performance requirements associated with these hazards.

      To date, no recalls have addressed the issue of pull cords ending in separate tassels or continuous loops that did not require an external tension device to be installed. Accordingly, just like a mandatory rule, relying on recalls to address hazards associated with continuous loops and pull cords would also require a solution from manufacturers to implement for the products that have been sold and for future production. We are also concerned that relying on recalls requires staff to establish independently that each window covering in question presents a substantial product hazard. In addition, a recall of an individual manufacturer's window covering has no binding effect on other manufacturers who may have similar products that present the same hazard.

      The Commission could also continue to pursue public information and education campaigns. In addition to compliance activities, CPSC has been warning parents of the danger of child strangulation due to corded window coverings since the first safety alert that was issued in 1985. CPSC has identified window coverings as one of the top five hidden home hazards.\22\ Every October, CPSC participates in National Window Covering Safety Month to urge parents and caregivers to check their window coverings for exposed and dangling cords and to take precautions. Both CPSC and the Window Covering Safety Council (WCSC) recommend cordless window coverings at homes where young children live or visit. CPSC reaches out to consumers to create awareness of the hazards associated with corded window coverings. Staff does not have information to assess the effectiveness of public education campaigns to date; however, the lack of an observable trend in the data over this time period indicates that such campaigns are not effectively reducing the risk.

      ---------------------------------------------------------------------------

      \22\ http://www.cpsc.gov/PageFiles/165163/hidden.pdf.

      ---------------------------------------------------------------------------

  9. Solicitation of Information and Comments

    This ANPR is the first step of a proceeding that could result in a mandatory rule for corded window covering products. We invite interested persons to submit comments on any aspect of the alternatives discussed above.

    Page 2349

    1. CPSA Requirements

      In accordance with section 9(a) of the CPSA, we also invite comments on:

      1. The risk of injury identified by the Commission, the regulatory alternatives being considered, and other possible alternatives for addressing the risk.

      2. Any existing standard or portion of a standard that could be issued as a proposed regulation.

      3. A statement of intention to modify or develop a voluntary standard to address the risk of injury discussed in this notice, along with a description of a plan (including a schedule) to do so.

    2. Information Specific to Corded Window Coverings

      In addition, we invite comments and information concerning the following:

      1. What corded window covering products should we include or exclude from the rulemaking and why? For example, we can include all corded window covering products, or we could just include products most likely to be found in homes and residences, and exclude larger products intended for commercial use.

      2. What possible warnings or instructions for corded window coverings could address the risk of injury? The current ANSI/WCMA standard requires warning labels, yet injuries and deaths continue. Are there additional warnings that could address the risk of injury?

      3. What possible performance requirements for window covering cords could address the risk of injury?

      4. Are there sections in a foreign or international standard that can be adopted as part of a mandatory rule?

      5. What are the current costs to manufacturers to comply with the labeling requirements in the current ANSI/WCMA voluntary standard? What are the potential costs to manufacturers of labeling or performance requirements?

      6. What are the potential benefits of a rule that would require warnings or instructions for corded window coverings?

      7. What are the potential benefits of a rule that would establish performance requirements for corded window coverings?

      8. What are the potential costs, economic and societal, of banning cords on window covering products? What alternative products would remain available?

      9. What is the potential impact on small entities of a rule based on the options presented above?

      10. Do consumers actually install and consistently use cord cleats and cord tensioning devices correctly? Are there other actions consumers take to reduce access to loops or cords?

      11. How can public education campaigns on window covering safety be improved? How can the effectiveness of such campaigns be measured?

      Market Information

      12. What percent or share of the market or how many products are in use for curtains and drapes are corded, cordless, or have inaccessible cords?

      13. How many window coverings are in use in U.S. households, by window covering type, if possible?

      14. What proportion of the window coverings in use are cordless, by window covering type, if possible?

      Cordless Products and Products With Inaccessible Cords

      15. What percent of the market (as measured by sales volume) constitutes cordless products?

      16. What percent of the market (as measured by sales volume) constitute products with inaccessible cords?

      17. What are annual dollar sales and unit sales volumes of cordless products, in total, and by product type, e.g. vertical blinds, horizontal blinds, curtains, and the various types of shades, such as cellular, pleated, roller, roll-up and Roman shades?

      18. What are annual dollar sales and unit sales volumes of products with inaccessible cords, in total and by product type, e.g. vertical blinds, horizontal blinds, curtains, and the various types of shades, such as cellular, pleated, roller, roll-up and Roman shades?

      19. What efforts have been made to market these solutions to consumers both at retail, online, and through direct outreach?

      20. What proportion of curtains or drapery coverings are used with looped or other types of cords for opening and closing?

      21. Information on size limitation(s) for cordless products. For example, would certain types of blinds or shades be too large or too heavy to be made into a cordless product?

      22. Information on size limitation(s) for products with inaccessible cords. For example, would certain types of blinds or shades be too large or too heavy to be made into products with inaccessible cords?

      23. Are there any other factors that would limit the production or use of cordless products and products with inaccessible cords?

      24. What is the size of the market for custom made cordless products, in annual dollar sales value or unit sales volume?

      25. What is the size of the market for custom-made products with inaccessible cords, in annual dollar sales value or unit sales volume?

      26. What is the expected product life of the various types of blinds and shades that are currently being sold in the marketplace?

      27. How does the product life of cordless products compare to (or differ from) the product life of corded products?

      28. How does the product life of products with inaccessible cords compare to (or differ from) the product life of corded products?

      29. Are cordless options available that would be inappropriate for populations with limited mobility or the elderly?

      30. Are products with inaccessible cords available that would be inappropriate for populations with limited mobility or the elderly?

      31. What technologies are available as alternatives to a corded operating system?

      32. What are the methods by which corded products can be converted into cordless products in the production process? What would the change in unit cost be for such conversions?

      33. What are the methods by which corded products can be converted into products with inaccessible cords in the production process? What would the change in unit cost be for such conversions?

      34. What are the potential benefits and limitations of tensioning devices that would render the window coverings completely inoperable if not installed properly?

      Information on Compliance With the Voluntary Standard

      35. As described in section VIII, one regulatory alternative is reliance on the voluntary standard issued by ANSI/WCMA.

      a. Is the ANSI/WCMA standard likely to result in the elimination or adequate reduction of the risk of injury associated with window covering cords?

      b. What effect, if any; would the obligation to report non-

      compliant products under 15 U.S.C. 2064(b)(l) have on compliance with the standard?

      36. What percentage of the market (in terms of sales) or producers comply with the voluntary standard? Should the Commission consider this percentage to be ``substantial compliance'' within the meaning of the CPSA?

      37. Does the current level of conformance to the voluntary standard differ for the various types of window coverings? If so, to what levels?

      Page 2350

      Information on Manufacturer Cost

      38. What is the typical difference in cost to produce cordless products, products with inaccessible cords, and corded window coverings? If possible, please provide the information by window covering type (e.g. vertical blinds, horizontal blinds, and the various types of shades, such as cellular, pleated, roller, roll-up and Roman)?

      39. What is the manufacturer's cost to produce various safety technologies, including research and development costs, and components, such as a retractable cord operating system, cord cleat, or cord shroud?

      40. How would manufacturing these products in large quantities change the cost? Please provide examples in terms of quantity and price change (%).

      Alberta E. Mills,

      Acting Secretary, Consumer Product Safety Commission.

      FR Doc. 2015-00566 Filed 1-15-15; 8:45 am

      BILLING CODE 6355-01-P

VLEX uses login cookies to provide you with a better browsing experience. If you click on 'Accept' or continue browsing this site we consider that you accept our cookie policy. ACCEPT