Energy conservation: Commercial and industrial equipment, energy efficiency program Electric motors; test procedures, labeling, and certification requirements; correction,
[Federal Register: January 13, 2000 (Volume 65, Number 9)]
[Corrections]
[Page 2227]
From the Federal Register Online via GPO Access [wais.access.gpo.gov]
[DOCID:fr13ja00-129]
[[Page 2227]]
DEPARTMENT OF ENERGY
Office of Energy Efficiency and Renewable Energy
10 CFR Part 431
[Docket No. EE-RM-96-400]
RIN 1904-AA82
Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures, Labeling, and Certification Requirements for Electric Motors
Correction
In rule document 99-21119beginning on page 54114, in the issue of Tuesday, October 5, 1999, make the following corrections:
Sec. 431.81 [Corrected]
-
On page 54161, in the second column, in Sec. 431.81, in the second line, ``[ONE YEAR AFTER PUBLICATION OF THIS RULE IN THE Federal Register]'' should read ``October 5, 2000''.
Sec. 431.123 [Corrected]
-
On page 54162, in the first column, in Sec. 431.123(a), in the second line, ``[insert date 30 days after publication in the Federal Register]'' should read ``November 4, 1999''.
-
On page 54163, in the first column, in Sec. 431.123(f)(2)(i)(B), in the first line, ``paragraph (f)(2)'' should read ``paragraph (f)(3)''.
Sec. 431.42 [Corrected]
-
On page 54158, in Sec. 431.42(a), the table is corrected to read as follows:
Nominal Full Load Efficiency
Open Motors (Number of poles)
Enclosed Motors (Number of poles)
6
4
2
6
4
2
Motor Horsepower/Standard Kilowatt Equivalent
1/.75.............................
80.0
82.5 ...........
80.0
82.5
75.5 1.5/1.1...........................
84.0
84.0
82.5
85.5
84.0
82.5 2/1.5.............................
85.5
84.0
84.0
86.5
84.0
84.0 3/2.2.............................
86.5
86.5
84.0
87.5
87.5
85.5 5/3.7.............................
87.5
87.5
85.5
87.5
87.5
87.5 7.5/5.5...........................
88.5
88.5
87.5
89.5
89.5
88.5 10/7.5............................
90.2
89.5
88.5
89.5
89.5
89.5 15/11.............................
90.2
91.0
89.5
90.2
91.0
90.2 20/15.............................
91.0
91.0
90.2
90.2
91.0
90.2 25/18.5...........................
91.7
91.7
91.0
91.7
92.4
91.0 30/22.............................
92.4
92.4
91.0
91.7
92.4
91.0 40/30.............................
93.0
93.0
91.7
93.0
93.0
91.7 50/37.............................
93.0
93.0
92.4
93.0
93.0
92.4 60/45.............................
93.6
93.6
93.0
93.6
93.6
93.0 75/55.............................
93.6
94.1
93.0
93.6
94.1
93.0 100/75............................
94.1
94.1
93.0
94.1
94.5
93.6 125/90............................
94.1
94.5
93.6
94.1
94.5
94.5 150/110...........................
94.5
95.0
93.6
95.0
95.0
94.5 200/150...........................
94.5
95.0
94.5
95.0
95.0
95.0
[FR Doc. C9-21119Filed1-12-00; 8:45 am]