Hazardous waste: Inorganic chemical manufacturing processes identification and listing, newly identified wastes land disposal restrictions, etc.; correction,

[Federal Register: April 9, 2002 (Volume 67, Number 68)]

[Corrections]

[Page 17119-17120]

From the Federal Register Online via GPO Access [wais.access.gpo.gov]

[DOCID:fr09ap02-112]

[[Page 17119]]

ENVIRONMENTAL PROTECTION AGENCY

40 CFR Part 268

[SWH-FRL-7099-2]

RIN 2050-AE49

Hazardous Waste Management System; Identification and Listing of Hazardous Waste: Inorganic Chemical Manufacturing Wastes; Land Disposal Restrictions for Newly Identified Wastes; and CERCLA Hazardous Substance Designation and Reportable Quantities

Correction

In rule document 01-27833beginning on page 58257 in the issue of Tuesday, November 20, 2001, make the following correction:

Due to several errors, the table titled ``TREATMENT STANDARDS FOR HADARDOUS WASTES'' that appears on pages 58298 and 58299 is being reprinted in its entirety.

Sec. 268.40 [Corrected]

* * * * *

Treatment Standards for Hazardous Wastes [Note: NA means not applicable]

Regulated hazardous constituent

Wastewaters

Nonwastewaters

Concentration in Waste code

Waste description and treatment/

Concentration in mg/ mg/kg \5\ unless regulatory Subcategory \1\

Common name

CAS \2\ No.

L \3\, or

noted as ``mg/L Technology Code \4\ TCLP'', or Technology Code

*

*

*

*

*

*

* K176............... Baghouse filters from the production Antimony

7440-36-0 1.9

1.15 mg/L TCLP of antimony oxide, including

Arsenic

7440-38-2 1.4

5.0 mg/L TCLP filters from the production of Cadmium

7440-43-9 0.69

0.11 mg/L TCLP intermediates (e.g., antimony metal Lead

7439-92-1 0.69

0.75 mg/L TCLP or crude antimony oxide)

Mercury

7439-97-6 0.15

0.025 mg/L TCLP K177............... Slag from the production of antimony Antimony

7440-36-0 1.9

1.15 mg/L TCLP oxide that is speculatively

Arsenic

7440-38-2 1.4

5.0 mg/L TCLP accumulated or disposed, including Lead

7439-92-1 0.69

0.75 mg/L TCLP slag from the production of intermediates (e.g., antimony metal or crude antimony oxide)

[[Page 17120]]

K178............... Residues from manufacturing and 1,2,3,4,6,7,8- Heptachlorodibenzo-p- 35822-39-4 0.000035 or CMBST 0.0025 or CMBST manufacturing-site storage of

dioxin (1,2,3,4,6,7,8-HpCDD)

\11\

\11\ ferric chloride from acids formed during the production of titanium 1,2,3,4,6,7,8-

67562-39-4 0.000035 or CMBST 0.0025 or CMBST dioxide using the chloride-ilmenite Heptachlorodibenzofuran

\11\

\11\ process.

(1,2,3,4,6,7,8-HpCDF)

1,2,3,4,7,8,9-

55673-89-7 0.000035 or CMBST 0.0025 or CMBST Heptachlorodibenzofuran

\11\

\11\ (1,2,3,4,7,8,9-HpCDF)

HxCDDs (All Hexachlorodibenzo-p-

34465-46-8 0.000063 or CMBST 0.001 or CMBST dioxins)

\11\

\11\

HxCDFs (All Hexachlorodibenzo-

55684-94-1 0.000063 or CMBST 0.001 or CMBST furans)

\11\

\11\

1,2,3,4,6,7,8,9- Octachlorodibenzo-p- 3268-87-9 0.000063 or CMBST 0.005 or CMBST dioxin (OCDD)

\11\

\11\

1,2,3,4,6,7,8,9-

39001-02-0 0.000063 or CMBST 0.005 or CMBST Octachlorodibenzofuran (OCDF)

\11\

\11\

PeCDDs (All Pentachlorodibenzo-p-

36088-22-9 0.000063 or CMBST 0.001 or CMBST dioxins)

\11\

\11\

PeCDFs (All Pentachlorodibenzo-

30402-15-4 0.000035 or CMBST 0.001 or CMBST furans)

\11\

\11\

TCDDs (All tetrachlorodibenzo-p-

41903-57-5 0.000063 or CMBST 0.001 or CMBST dioxins)

\11\

\11\

TCDFs (All tetrachlorodibenzo-

55722-27-5 0.000063 or CMBST 0.001 or CMBST furans)

\11\

\11\

Thallium

7440-28-0 1.4

0.20 mg/L TCLP

*

*

*

*

*

*

*

*

*

*

*

* Footnotes to Treatment Standard Table 268.40: \1\ The waste descriptions provided in this table do not replace waste descriptions in 40 CFR part 261. Descriptions of Treatment/Regulatory Subcategories are provided, as needed, to distinguish between applicability of different standards. \2\ CAS means Chemical Abstract Services. When the waste code and/or regulated constituents are described as a combination of a chemical with its salts and/or esters, the CAS number is given for the parent compound only. \3\ Concentration standards for wastewaters are expressed in mg/L and are based on analysis of composite samples. \4\ All treatment standards expressed as a Technology Code or combination of Technology Codes are explained in detail in 40 CFR 268.42 Table 1-- Technology Codes and Descriptions of Technology-Based Standards. \5\ Except for Metals (EP or TCLP) and Cyanides (Total and Amenable) the nonwastewater treatment standards expressed as a concentration were established, in part, based upon incineration in units operated in accordance with the technical requirements of 40 CFR part 264, Subpart O or 40 CFR part 265, Subpart O, or based upon combustion in fuel substitution units operating in accordance with applicable technical requirements. A facility may comply with these treatment standards according to provisions in 40 CFR 268.40(d). All concentration standards for nonwastewaters are based on analysis of grab samples. *

*

*

*

* \11\ For these wastes, the definition of CMBST is limited to: (1) combustion units operating under 40 CFR 266, (2) combustion units permitted under 40 CFR part 264, Subpart O, or (3) combustion units operating under 40 CFR 265, Subpart O, which have obtained a determination of equivalent treatment under 268.42(b). *

*

*

*

*

[FR Doc. C1-27833Filed4-8-02; 8:45 am]