Southern Nuclear Operating Company, Inc., Vogtle Electric Generating Plant, Units 3 and 4; RNS Pump Testing ITAAC Changes

Published date28 February 2019
Citation84 FR 6837
Record Number2019-03482
SectionNotices
CourtNuclear Regulatory Commission
Federal Register, Volume 84 Issue 40 (Thursday, February 28, 2019)
[Federal Register Volume 84, Number 40 (Thursday, February 28, 2019)]
                [Notices]
                [Pages 6837-6838]
                From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
                [FR Doc No: 2019-03482]
                [[Page 6837]]
                =======================================================================
                -----------------------------------------------------------------------
                NUCLEAR REGULATORY COMMISSION
                [Docket Nos. 52-025 and 52-026; NRC-2008-0252]
                Southern Nuclear Operating Company, Inc., Vogtle Electric
                Generating Plant, Units 3 and 4; RNS Pump Testing ITAAC Changes
                AGENCY: Nuclear Regulatory Commission.
                ACTION: Exemption and combined license amendment; issuance.
                -----------------------------------------------------------------------
                SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is granting an
                exemption to allow a departure from the certification information of
                Tier 1 of the generic design control document (DCD) and is issuing
                License Amendment Nos. 152 and 151 to Combined Licenses (COL), NPF-91
                and NPF-92, respectively. The COLs were issued to Southern Nuclear
                Operating Company, Inc., and Georgia Power Company, Oglethorpe Power
                Corporation, MEAG Power SPVM, LLC, MEAG Power SPVJ, LLC, MEAG Power
                SPVP, LLC, and the City of Dalton, Georgia (collectively SNC); for
                construction and operation of the Vogtle Electric Generating Plant
                (VEGP) Units 3 and 4, located in Burke County, Georgia.
                 The granting of the exemption allows the changes to Tier 1
                information asked for in the amendment. Because the acceptability of
                the exemption was determined in part by the acceptability of the
                amendment, the exemption and amendment are being issued concurrently.
                DATES: The exemption and amendment were issued on January 28, 2019.
                ADDRESSES: Please refer to Docket ID NRC-2008-0252 when contacting the
                NRC about the availability of information regarding this document. You
                may obtain publicly-available information related to this document
                using any of the following methods:
                 Federal Rulemaking Website: Go to http://www.regulations.gov and search for Docket ID NRC-2008-0252. Address
                questions about Docket IDs in Regulations.gov to Krupskaya Castellon;
                telephone: 301-287-9221; email: Krupskaya.Castellon@nrc.gov. For
                technical questions, contact the individual listed in the FOR FURTHER
                INFORMATION CONTACT section of this document.
                 NRC's Agencywide Documents Access and Management System
                (ADAMS): You may obtain publicly-available documents online in the
                ADAMS Public Documents collection at http://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``ADAMS Public Documents'' and
                then select ``Begin Web-based ADAMS Search.'' For problems with ADAMS,
                please contact the NRC's Public Document Room (PDR) reference staff at
                1-800-397-4209, 301-415-4737, or by email to pdr.resource@nrc.gov. The
                ADAMS accession number for each document referenced (if it is available
                in ADAMS) is provided the first time that it is mentioned in this
                document. The request for the amendment and exemption was submitted by
                letter dated by July 19, 2018 (ADAMS Accession No. ML18200A415).
                 NRC's PDR: You may examine and purchase copies of public
                documents at the NRC's PDR, Room O1-F21, One White Flint North, 11555
                Rockville Pike, Rockville, Maryland 20852.
                FOR FURTHER INFORMATION CONTACT: Chandu Patel, Office of New Reactors,
                U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001;
                telephone: 301-415-3025; email: Chandu.Patel@nrc.gov.
                SUPPLEMENTARY INFORMATION:
                I. Introduction
                 The NRC is granting an exemption from paragraph B of Section III,
                ``Scope and Contents,'' of Appendix D, ``Design Certification Rule for
                the AP1000,'' to part 52 of title 10 of the Code of Federal Regulations
                (10 CFR), and issuing License Amendment Nos. 152 and 151 to COLs, NPF-
                91 and NPF-92, to SNC. The exemption is required by paragraph A.4 of
                Section VIII, ``Processes for Changes and Departures,'' Appendix D, to
                10 CFR part 52 to allow SNC to depart from Tier 1 information. With the
                requested amendment, SNC proposed changes to COL Appendix C (and plant-
                specific DCD Tier 1) to revise Inspections, Tests, Analyses, and
                Acceptance Criteria (ITAAC) related to flow testing of low pressure
                makeup from the cask loading pit to the reactor coolant system via the
                normal residual heat removal system (RNS) and RNS pump testing at
                reduced inventory.
                 Part of the justification for granting the exemption was provided
                by the review of the amendment. Because the exemption is necessary in
                order to issue the requested license amendment, the NRC granted the
                exemption and issued the amendment concurrently, rather than in
                sequence. This included issuing a combined safety evaluation containing
                the NRC staff's review of both the exemption request and the license
                amendment. The exemption met all applicable regulatory criteria set
                forth in Sec. Sec. 50.12, 52.7, and section VIII.A.4 of Appendix D to
                10 CFR part 52. The license amendment was found to be acceptable as
                well. The combined safety evaluation is available in ADAMS under
                Accession No. ML19003A487.
                 Identical exemption documents (except for referenced unit numbers
                and license numbers) were issued to SNC for VEGP Units 3 and 4 (COLs
                NPF-91 and NPF-92). The exemption documents for VEGP Units 3 and 4 can
                be found in ADAMS under Accession Nos. ML19003A481 and ML19003A482,
                respectively. The exemption is reproduced (with the exception of
                abbreviated titles and additional citations) in Section II of this
                document. The amendment documents for COLs, NPF-91 and NPF-92 are
                available in ADAMS under Accession Nos. ML19003A483 and ML19003A485,
                respectively. A summary of the amendment documents is provided in
                Section III of this document.
                II. Exemption
                 Reproduced below is the exemption document issued to VEGP Units 3
                and Unit 4. It makes reference to the combined safety evaluation that
                provides the reasoning for the findings made by the NRC (and listed
                under Item 1) in order to grant the exemption:
                 1. In a letter dated July 19, 2018, Southern Nuclear Operating
                Company requested from the Commission an exemption to allow departures
                from Tier 1 information in the certified DCD incorporated by reference
                in 10 CFR part 52, Appendix D, as part of license amendment request 18-
                016, ``RNS Pump Testing ITAAC Changes.''
                 For the reasons set forth in section 3.2 of the NRC staff's Safety
                Evaluation, which can be found in ADAMS under Accession No.
                ML19003A487, the Commission finds that:
                 A. The exemption is authorized by law;
                 B. the exemption presents no undue risk to public health and
                safety;
                 C. the exemption is consistent with the common defense and
                security;
                 D. special circumstances are present in that the application of the
                rule in this circumstance is not necessary to serve the underlying
                purpose of the rule;
                 E. the special circumstances outweigh any decrease in safety that
                may result from the reduction in standardization caused by the
                exemption; and
                 F. the exemption will not result in a significant decrease in the
                level of safety otherwise provided by the design.
                 2. Accordingly, SNC is granted an exemption from the certified DCD
                Tier 1 information, with corresponding changes to Appendix C of the
                Facility Combined License, as described in the request dated July 19,
                2018. This
                [[Page 6838]]
                exemption is related to, and necessary for the granting of License
                Amendment No. 152 [for Unit 3, 151 for Unit 4], which is being issued
                concurrently with this exemption.
                 3. As explained in section 5.0 of the NRC staff's Safety Evaluation
                (ADAMS Accession No. ML19003A487), this exemption meets the eligibility
                criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9).
                Therefore, pursuant to 10 CFR 51.22(b), no environmental impact
                statement or environmental assessment needs to be prepared in
                connection with the issuance of the exemption.
                 4. This exemption is effective as of the date of its issuance.
                III. License Amendment Request
                 By letter dated July 19, 2018 (ADAMS Accession No. ML18200A415),
                SNC requested that the NRC amend the COLs for VEGP, Units 3 and 4,
                COLs, NPF-91 and NPF-92. The proposed amendment is described in Section
                I of this Federal Register notice.
                 The Commission has determined for these amendments that the
                application complies with the standards and requirements of the Atomic
                Energy Act of 1954, as amended (the Act), and the Commission's rules
                and regulations. The Commission has made appropriate findings as
                required by the Act and the Commission's rules and regulations in 10
                CFR Chapter I, which are set forth in the license amendment.
                 A notice of consideration of issuance of amendment to facility
                operating license or COL, as applicable, proposed no significant
                hazards consideration determination, and opportunity for a hearing in
                connection with these actions, was published in the Federal Register on
                September 25, 2018 (83 FR 48463). No comments were received during the
                30-day comment period.
                 The Commission has determined that these amendments satisfy the
                criteria for categorical exclusion in accordance with 10 CFR 51.22.
                Therefore, pursuant to 10 CFR 51.22(b), no environmental impact
                statement or environmental assessment need be prepared for these
                amendments.
                IV. Conclusion
                 Using the reasons set forth in the combined safety evaluation, the
                staff granted the exemptions and issued the amendments that SNC
                requested on July 19, 2018.
                 The exemptions and amendments were issued on January 28, 2019, as
                part of a combined package to SNC (ADAMS Package Accession No.
                ML19003A479).
                 Dated at Rockville, Maryland, this 25th day of February 2019.
                 For the Nuclear Regulatory Commission.
                Jennifer L. Dixon-Herrity,
                Chief, Licensing Branch 2, Division of Licensing, Siting, and
                Environmental Analysis, Office of New Reactors.
                [FR Doc. 2019-03482 Filed 2-27-19; 8:45 am]